📄 rfc2155.txt
字号:
STATUS current
DESCRIPTION
"Indicates whether this node has interchange node support.
This object corresponds to cv4580, byte 9, bit 1."
::= { appnNnUniqueInfoAndCaps 7 }
Clouston & Moore Standards Track [Page 21]
RFC 2155 Definitions of Managed Objects for APPN June 1997
appnNodeNnExteBorderSup OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates whether this node has extended border node support.
This object corresponds to cv4580, byte 9, bit 2."
::= { appnNnUniqueInfoAndCaps 8 }
appnNodeNnSafeStoreFreq OBJECT-TYPE
SYNTAX INTEGER (0..32767)
UNITS "TDUs"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The topology safe store frequency.
If this number is not zero, then the topology database is saved
each time the total number of topology database updates (TDUs)
received by this node increases by this number. A value of
zero indicates that the topology database is not being saved."
::= { appnNnUniqueInfoAndCaps 9 }
appnNodeNnRsn OBJECT-TYPE
SYNTAX Unsigned32
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Resource sequence number for this node, which it assigns and
controls.
This object corresponds to the numeric value in cv4580, bytes
2-5."
::= { appnNnUniqueInfoAndCaps 10 }
appnNodeNnCongested OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates whether this node is congested. Other network nodes
stop routing traffic to this node while this flag is on.
Clouston & Moore Standards Track [Page 22]
RFC 2155 Definitions of Managed Objects for APPN June 1997
This object corresponds to cv4580, byte 7, bit 0."
::= { appnNnUniqueInfoAndCaps 11 }
appnNodeNnIsrDepleted OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicate whether intermediated session routing resources are
depleted. Other network nodes stop routing traffic through
this node while this flag is on.
This object corresponds to cv4580, byte 7, bit 1."
::= { appnNnUniqueInfoAndCaps 12 }
appnNodeNnQuiescing OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates whether the node is quiescing.
This object corresponds to cv4580, byte 7, bit 5."
::= { appnNnUniqueInfoAndCaps 13 }
appnNodeNnGateway OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates whether the node has gateway services support.
This object corresponds to cv4580, byte 8, bit 0."
::= { appnNnUniqueInfoAndCaps 14 }
-- *********************************************************************
-- APPN End Node Information
appnNodeEnModeCosMap OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
Clouston & Moore Standards Track [Page 23]
RFC 2155 Definitions of Managed Objects for APPN June 1997
"Indicates whether this end node supports mode name to COS name
mapping."
::= { appnEnUniqueCaps 1 }
appnNodeEnNnServer OBJECT-TYPE
SYNTAX OCTET STRING (SIZE (0 | 3..17))
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The fully qualified name of the current NN server for this end
node. An NN server is identified using the format specified in
the SnaControlPointName textual convention. The value is a
zero-length string when there is no active NN server."
::= { appnEnUniqueCaps 2 }
appnNodeEnLuSearch OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates whether the node is to be searched for LUs as part
of a network broadcast search."
::= { appnEnUniqueCaps 3 }
-- *********************************************************************
-- APPN Port information
--
appnPortTable OBJECT-TYPE
SYNTAX SEQUENCE OF AppnPortEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Port table describes the configuration and current status
of the ports used by APPN. When it is known to the APPN
component, an OBJECT IDENTIFIER pointing to additional
information related to the port is included. This may, but
need not, be a RowPointer to an ifTable entry for a DLC
interface immediately 'below' the port."
::= { appnPortInformation 1 }
appnPortEntry OBJECT-TYPE
SYNTAX AppnPortEntry
MAX-ACCESS not-accessible
Clouston & Moore Standards Track [Page 24]
RFC 2155 Definitions of Managed Objects for APPN June 1997
STATUS current
DESCRIPTION
"The port name is used as the index to this table."
INDEX
{ appnPortName }
::= { appnPortTable 1 }
AppnPortEntry ::= SEQUENCE {
appnPortName DisplayString,
appnPortCommand INTEGER,
appnPortOperState INTEGER,
appnPortDlcType IANAifType,
appnPortPortType INTEGER,
appnPortSIMRIM TruthValue,
appnPortLsRole INTEGER,
appnPortNegotLs TruthValue,
appnPortDynamicLinkSupport TruthValue,
appnPortMaxRcvBtuSize INTEGER,
appnPortMaxIframeWindow Gauge32,
appnPortDefLsGoodXids AppnPortCounter,
appnPortDefLsBadXids AppnPortCounter,
appnPortDynLsGoodXids AppnPortCounter,
appnPortDynLsBadXids AppnPortCounter,
appnPortSpecific RowPointer,
appnPortDlcLocalAddr DisplayableDlcAddress,
appnPortCounterDisconTime TimeStamp
}
appnPortName OBJECT-TYPE
SYNTAX DisplayString (SIZE (1..10))
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"Administratively assigned name for this APPN port."
::= { appnPortEntry 1 }
appnPortCommand OBJECT-TYPE
SYNTAX INTEGER {
deactivate(1),
activate(2),
recycle(3),
ready(4)
}
MAX-ACCESS read-write
STATUS current
Clouston & Moore Standards Track [Page 25]
RFC 2155 Definitions of Managed Objects for APPN June 1997
DESCRIPTION
"Object by which a Management Station can activate, deactivate,
or recycle (i.e., cause to be deactivated and then immediately
activated) a port, by setting the value to activate(1),
deactivate(2), or recycle(3), respectively. The value ready(4)
is returned on GET operations until a SET has been processed;
after that the value received on the most recent SET is
returned."
::= { appnPortEntry 2 }
appnPortOperState OBJECT-TYPE
SYNTAX INTEGER {
inactive(1),
pendactive(2),
active(3),
pendinact(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates the current state of this port:
inactive(1) - port is inactive
pendactive(2) - port is pending active
active(3) - port is active
pendinact(4) - port is pending inactive"
::= { appnPortEntry 3 }
appnPortDlcType OBJECT-TYPE
SYNTAX IANAifType
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The type of DLC interface, distinguished according to the
protocol immediately 'below' this layer."
::= { appnPortEntry 4 }
appnPortPortType OBJECT-TYPE
SYNTAX INTEGER {
leased(1),
switched(2),
sharedAccessFacilities(3)
}
MAX-ACCESS read-only
Clouston & Moore Standards Track [Page 26]
RFC 2155 Definitions of Managed Objects for APPN June 1997
STATUS current
DESCRIPTION
"Identifies the type of line used by this port:
leased(1) - leased line
switched(2) - switched line
sharedAccessFacilities(3) - shared access facility, such
as a LAN."
::= { appnPortEntry 5 }
appnPortSIMRIM OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates whether Set Initialization Mode (SIM) and Receive
Initialization Mode (RIM) are supported for this port."
::= { appnPortEntry 6 }
appnPortLsRole OBJECT-TYPE
SYNTAX INTEGER {
primary(1),
secondary(2),
negotiable(3),
abm(4)
}
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Initial role for link stations activated through this port.
The values map to the following settings in the initial XID,
where 'ABM' indicates asynchronous balanced mode and 'NRM'
indicated normal response mode:
primary(1): ABM support = 0 ( = NRM)
role = 01 ( = primary)
secondary(2): ABM support = 0 ( = NRM)
role = 00 ( = secondary)
negotiable(3): ABM support = 0 ( = NRM)
role = 11 ( = negotiable)
abm(4): ABM support = 1 ( = ABM)
role = 11 ( = negotiable)"
::= { appnPortEntry 7 }
appnPortNegotLs OBJECT-TYPE
Clouston & Moore Standards Track [Page 27]
RFC 2155 Definitions of Managed Objects for APPN June 1997
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates whether the node supports negotiable link stations
for this port."
::= { appnPortEntry 8 }
appnPortDynamicLinkSupport OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Indicates whether this node allows call-in on this port from
nodes not defined locally."
::= { appnPortEntry 9 }
appnPortMaxRcvBtuSize OBJECT-TYPE
SYNTAX INTEGER (99..32767)
UNITS "bytes"
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"Maximum Basic Transmission Unit (BTU) size that a link station
on this port can receive.
This object corresponds to bytes 21-22 of XID3."
::= { appnPortEntry 10 }
appnPortMaxIframeWindow OBJECT-TYPE
SYNTAX Gauge32
UNITS "I-frames"
MAX-ACCESS read-only
STATUS current
DESCRIPTION