📄 rfc2558.txt
字号:
Tesink Standards Track [Page 25]
RFC 2558 SONET/SDH Objects March 1999
-- The SONET/SDH Section Interval Table
-- contains various statistics
-- collected by each system over a maximum
-- of the previous 24 hours of
-- operation. The past 24 hours may be broken into 96
-- completed 15 minute intervals.
-- A system is required to store at
-- least 4 completed 15 minute interval.
-- The default value is 32 intervals.
sonetSectionIntervalTable OBJECT-TYPE
SYNTAX SEQUENCE OF SonetSectionIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The SONET/SDH Section Interval table."
::= { sonetSection 2 }
sonetSectionIntervalEntry OBJECT-TYPE
SYNTAX SonetSectionIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the SONET/SDH Section Interval table."
INDEX { ifIndex,
sonetSectionIntervalNumber }
::= { sonetSectionIntervalTable 1 }
SonetSectionIntervalEntry ::=
SEQUENCE {
sonetSectionIntervalNumber Integer32,
sonetSectionIntervalESs PerfIntervalCount,
sonetSectionIntervalSESs PerfIntervalCount,
sonetSectionIntervalSEFSs PerfIntervalCount,
sonetSectionIntervalCVs PerfIntervalCount,
sonetSectionIntervalValidData TruthValue
}
sonetSectionIntervalNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number between 1 and 96, which identifies the
interval for which the set of statistics is available.
The interval identified by 1 is the most recently
completed 15 minute interval,
Tesink Standards Track [Page 26]
RFC 2558 SONET/SDH Objects March 1999
and the interval identified
by N is the interval immediately preceding the
one identified
by N-1."
::= { sonetSectionIntervalEntry 1 }
sonetSectionIntervalESs OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of
Errored Seconds encountered
by a SONET/SDH Section in a
particular 15-minute interval
in the past 24 hours."
::= { sonetSectionIntervalEntry 2 }
sonetSectionIntervalSESs OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of
Severely Errored Seconds
encountered by a SONET/SDH Section in a
particular 15-minute interval
in the past 24 hours."
::= { sonetSectionIntervalEntry 3 }
sonetSectionIntervalSEFSs OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of
Severely Errored Framing Seconds
encountered by a SONET/SDH Section in a
particular 15-minute interval
in the past 24 hours."
::= { sonetSectionIntervalEntry 4 }
sonetSectionIntervalCVs OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Coding
Tesink Standards Track [Page 27]
RFC 2558 SONET/SDH Objects March 1999
Violations encountered by a
SONET/SDH Section in a particular 15-minute interval
in the past 24 hours."
::= { sonetSectionIntervalEntry 5 }
sonetSectionIntervalValidData OBJECT-TYPE
SYNTAX TruthValue
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable indicates if the data for this
interval is valid."
::= { sonetSectionIntervalEntry 6 }
-- the SONET/SDH Line group
-- this group consists of 2 tables:
-- - the SONET/SDH Line Current Table
-- - the SONET/SDH Line Interval Table
-- the SONET/SDH Line Current Table
-- The SONET/SDH Line
-- current table contains various statistics
-- being collected for the current 15 minute interval.
sonetLineCurrentTable OBJECT-TYPE
SYNTAX SEQUENCE OF SonetLineCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The SONET/SDH Line Current table."
::= { sonetLine 1 }
sonetLineCurrentEntry OBJECT-TYPE
SYNTAX SonetLineCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the SONET/SDH Line Current table."
INDEX { ifIndex }
::= { sonetLineCurrentTable 1 }
SonetLineCurrentEntry ::=
SEQUENCE {
sonetLineCurrentStatus Integer32,
Tesink Standards Track [Page 28]
RFC 2558 SONET/SDH Objects March 1999
sonetLineCurrentESs PerfCurrentCount,
sonetLineCurrentSESs PerfCurrentCount,
sonetLineCurrentCVs PerfCurrentCount,
sonetLineCurrentUASs PerfCurrentCount
}
sonetLineCurrentStatus OBJECT-TYPE
SYNTAX Integer32 (1..6)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable indicates the
status of the interface.
The sonetLineCurrentStatus
is a bit map represented
as a sum, therefore,
it can represent multiple defects
simultaneously.
The sonetLineNoDefect should be
set if and only if
no other flag is set.
The various bit positions are:
1 sonetLineNoDefect
2 sonetLineAIS
4 sonetLineRDI"
::= { sonetLineCurrentEntry 1 }
sonetLineCurrentESs OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Errored
Seconds encountered by a SONET/SDH
Line in the current 15 minute interval."
::= { sonetLineCurrentEntry 2 }
sonetLineCurrentSESs OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of
Severely Errored Seconds
encountered by a SONET/SDH Line in the current 15
minute
Tesink Standards Track [Page 29]
RFC 2558 SONET/SDH Objects March 1999
interval."
::= { sonetLineCurrentEntry 3 }
sonetLineCurrentCVs OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Coding
Violations encountered by a
SONET/SDH Line in the current 15 minute interval."
::= { sonetLineCurrentEntry 4 }
sonetLineCurrentUASs OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of
Unavailable Seconds
encountered by a SONET/SDH Line in the current 15
minute
interval."
::= { sonetLineCurrentEntry 5 }
-- the SONET/SDH Line Interval Table
-- The SONET/SDH Line Interval Table
-- contains various statistics
-- collected by each system over a maximum
-- of the previous 24 hours of
-- operation. The past 24 hours may be broken into 96
-- completed 15 minute intervals.
-- A system is required to store at
-- least 4 completed 15 minute interval.
-- The default value is 32 intervals.
sonetLineIntervalTable OBJECT-TYPE
SYNTAX SEQUENCE OF SonetLineIntervalEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The SONET/SDH Line Interval table."
::= { sonetLine 2 }
sonetLineIntervalEntry OBJECT-TYPE
SYNTAX SonetLineIntervalEntry
Tesink Standards Track [Page 30]
RFC 2558 SONET/SDH Objects March 1999
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the SONET/SDH Line Interval table."
INDEX { ifIndex,
sonetLineIntervalNumber }
::= { sonetLineIntervalTable 1 }
SonetLineIntervalEntry ::=
SEQUENCE {
sonetLineIntervalNumber Integer32,
sonetLineIntervalESs PerfIntervalCount,
sonetLineIntervalSESs PerfIntervalCount,
sonetLineIntervalCVs PerfIntervalCount,
sonetLineIntervalUASs PerfIntervalCount,
sonetLineIntervalValidData TruthValue
}
sonetLineIntervalNumber OBJECT-TYPE
SYNTAX Integer32 (1..96)
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"A number between 1 and 96, which identifies the
interval for which the set of statistics is available.
The interval identified by 1 is the most recently
completed 15 minute interval,
and the interval identified
by N is the interval immediately preceding the
one identified
by N-1."
::= { sonetLineIntervalEntry 1 }
sonetLineIntervalESs OBJECT-TYPE
SYNTAX PerfIntervalCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of
Errored Seconds encountered
by a SONET/SDH Line in a
particular 15-minute interval
in the past 24 hours."
::= { sonetLineIntervalEntry 2 }
sonetLineIntervalSESs OBJECT-TYPE
SYNTAX PerfIntervalCount
Tesink Standards Track [Page 31]
RFC 2558 SONET/SDH Objects March 1999
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter assoc