📄 rfc2558.txt
字号:
SonetMediumEntry ::=
SEQUENCE {
sonetMediumType INTEGER,
sonetMediumTimeElapsed Integer32,
sonetMediumValidIntervals Integer32,
sonetMediumLineCoding INTEGER,
sonetMediumLineType INTEGER,
sonetMediumCircuitIdentifier DisplayString,
sonetMediumInvalidIntervals Integer32,
sonetMediumLoopbackConfig BITS
}
Tesink Standards Track [Page 19]
RFC 2558 SONET/SDH Objects March 1999
sonetMediumType OBJECT-TYPE
SYNTAX INTEGER {
sonet(1),
sdh(2)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable identifies whether a SONET
or a SDH signal is used across this interface."
::= { sonetMediumEntry 1 }
sonetMediumTimeElapsed OBJECT-TYPE
SYNTAX Integer32 (1..900)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of seconds, including partial seconds,
that have elapsed since the beginning of the current
measurement period. If, for some reason, such as an
adjustment in the system's time-of-day clock, the
current interval exceeds the maximum value, the
agent will return the maximum value."
::= { sonetMediumEntry 2 }
sonetMediumValidIntervals OBJECT-TYPE
SYNTAX Integer32 (0..96)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of previous 15-minute intervals
for which data was collected.
A SONET/SDH interface must be capable
of supporting at least n intervals.
The minimum value of n is 4.
The default of n is 32.
The maximum value of n is 96.
The value will be <n> unless the measurement was
(re-)started within the last (<n>*15) minutes, in which
case the value will be the number of complete 15
minute intervals for which the agent has at least
some data. In certain cases (e.g., in the case
where the agent is a proxy) it is possible that some
intervals are unavailable. In this case, this
interval is the maximum interval number for
which data is available. "
::= { sonetMediumEntry 3 }
Tesink Standards Track [Page 20]
RFC 2558 SONET/SDH Objects March 1999
sonetMediumLineCoding OBJECT-TYPE
SYNTAX INTEGER {
sonetMediumOther(1),
sonetMediumB3ZS(2),
sonetMediumCMI(3),
sonetMediumNRZ(4),
sonetMediumRZ(5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable describes the line coding for
this interface. The B3ZS and CMI are used for
electrical SONET/SDH signals (STS-1 and STS-3).
The Non-Return to Zero (NRZ) and the Return
to Zero are used for optical SONET/SDH signals."
::= { sonetMediumEntry 4 }
sonetMediumLineType OBJECT-TYPE
SYNTAX INTEGER {
sonetOther(1),
sonetShortSingleMode(2),
sonetLongSingleMode(3),
sonetMultiMode(4),
sonetCoax(5),
sonetUTP(6)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable describes the line type for
this interface. The line types are
Short and Long Range
Single Mode fiber or Multi-Mode fiber interfaces,
and coax and UTP for electrical interfaces. The
value sonetOther should be used when the Line Type is
not one of the listed values."
::= { sonetMediumEntry 5 }
sonetMediumCircuitIdentifier OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255))
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"This variable contains the transmission
vendor's circuit identifier, for the
purpose of facilitating troubleshooting.
Note that the circuit identifier, if available,
Tesink Standards Track [Page 21]
RFC 2558 SONET/SDH Objects March 1999
is also represented by ifPhysAddress."
::= { sonetMediumEntry 6 }
sonetMediumInvalidIntervals OBJECT-TYPE
SYNTAX Integer32 (0..96)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The number of intervals in the range from
0 to sonetMediumValidIntervals for which no
data is available. This object will typically
be zero except in cases where the data for some
intervals are not available (e.g., in proxy
situations)."
::= { sonetMediumEntry 7 }
sonetMediumLoopbackConfig OBJECT-TYPE
SYNTAX BITS {
sonetNoLoop(0),
sonetFacilityLoop(1),
sonetTerminalLoop(2),
sonetOtherLoop(3) }
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"The current loopback state of the SONET/SDH interface. The
values mean:
sonetNoLoop
Not in the loopback state. A device that is not
capable of performing a loopback on this interface
shall always return this value.
sonetFacilityLoop
The received signal at this interface is looped back
out through the corresponding transmitter in the return
direction.
sonetTerminalLoop
The signal that is about to be transmitted is connected
to the associated incoming receiver.
sonetOtherLoop
Loopbacks that are not defined here."
::= { sonetMediumEntry 8 }
sonetSESthresholdSet OBJECT-TYPE
SYNTAX INTEGER {
Tesink Standards Track [Page 22]
RFC 2558 SONET/SDH Objects March 1999
other(1),
Bellcore1991(2),
ansi1993(3),
itu1995(4),
ansi1997(5)
}
MAX-ACCESS read-write
STATUS current
DESCRIPTION
"An enumerated integer indicating which
recognized set of SES thresholds that
the agent uses for determining severely
errored seconds and unavailable time.
other(1)
None of the following.
Bellcore1991(2)
Bellcore TR-NWT-000253, 1991 [32], or
ANSI T1M1.3/93-005R2, 1993 [22].
See also Appendix B.
ansi1993(3)
ANSI T1.231, 1993 [31], or
Bellcore GR-253-CORE, Issue 2, 1995 [34]
itu1995(4)
ITU Recommendation G.826, 1995 [33]
ansi1997(5)
ANSI T1.231, 1997 [35]
If a manager changes the value of this
object then the SES statistics collected
prior to this change must be invalidated."
::= { sonetMedium 2 }
-- the SONET/SDH Section group
-- this group consists of 2 tables:
-- - the SONET/SDH Section Current Table
-- - the SONET/SDH Section Interval Table
-- the SONET/SDH Section Current Table
-- The SONET/SDH Section
Tesink Standards Track [Page 23]
RFC 2558 SONET/SDH Objects March 1999
-- current table contains various statistics
-- being collected for the current 15 minute interval.
sonetSectionCurrentTable OBJECT-TYPE
SYNTAX SEQUENCE OF SonetSectionCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The SONET/SDH Section Current table."
::= { sonetSection 1 }
sonetSectionCurrentEntry OBJECT-TYPE
SYNTAX SonetSectionCurrentEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the SONET/SDH Section Current table."
INDEX { ifIndex }
::= { sonetSectionCurrentTable 1 }
SonetSectionCurrentEntry ::=
SEQUENCE {
sonetSectionCurrentStatus Integer32,
sonetSectionCurrentESs PerfCurrentCount,
sonetSectionCurrentSESs PerfCurrentCount,
sonetSectionCurrentSEFSs PerfCurrentCount,
sonetSectionCurrentCVs PerfCurrentCount
}
sonetSectionCurrentStatus OBJECT-TYPE
SYNTAX Integer32 (1..6)
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"This variable indicates the
status of the interface.
The sonetSectionCurrentStatus
is a bit map represented
as a sum, therefore,
it can represent multiple defects
simultaneously.
The sonetSectionNoDefect should be
set if and only if
no other flag is set.
The various bit positions are:
1 sonetSectionNoDefect
Tesink Standards Track [Page 24]
RFC 2558 SONET/SDH Objects March 1999
2 sonetSectionLOS
4 sonetSectionLOF"
::= { sonetSectionCurrentEntry 1 }
sonetSectionCurrentESs OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Errored
Seconds encountered by a SONET/SDH
Section in the current 15 minute interval."
::= { sonetSectionCurrentEntry 2 }
sonetSectionCurrentSESs OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of
Severely Errored Seconds
encountered by a SONET/SDH Section in the current 15
minute interval."
::= { sonetSectionCurrentEntry 3 }
sonetSectionCurrentSEFSs OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of
Severely Errored Framing Seconds
encountered by a SONET/SDH Section in the current
15 minute interval."
::= { sonetSectionCurrentEntry 4 }
sonetSectionCurrentCVs OBJECT-TYPE
SYNTAX PerfCurrentCount
MAX-ACCESS read-only
STATUS current
DESCRIPTION
"The counter associated with the number of Coding
Violations encountered by a
SONET/SDH Section in the current 15 minute interval."
::= { sonetSectionCurrentEntry 5 }
-- the SONET/SDH Section Interval Table