📄 rfc1289.txt
字号:
other (14),
fddi (15)
}
ACCESS read-only
STATUS mandatory
DESCRIPTION
DECnet Phase IV MIB Working Group [Page 26]
RFC 1289 DECnet Phase IV MIB December 1991
"Represents the type of the circuit. For X.25 circuits,
the value must be set to X25. For DDCMP and Ethernet
circuits it is read only and is the same value as the
protocol of the associated line.
NOTE: Values 1 - 5 are incremented by one compared to the
standard DECnet values in order to maintain compliance
with RFC 1155."
::= { phivCircuitParametersEntry 7 }
phivCircuitService OBJECT-TYPE
SYNTAX INTEGER {
enabled (1),
disabled (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This value indicates whether or not Network Management
allows service operations on a circuit. The values for
service-control are as follows:
ENABLED SERVICE state and/or service functions are
allowed.
DISABLED SERVICE state and/or service functions are not
allowed.
NOTE: These values are incremented by one compared to the
standard DECnet values in order to maintain compliance
with RFC 1155."
::= { phivCircuitParametersEntry 8 }
phivCircuitExecCost OBJECT-TYPE
SYNTAX INTEGER (1..25)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This value represents the routing cost of the circuit.
Routing sends messages along the path between two nodes
having the smallest cost."
::= { phivCircuitParametersEntry 9 }
phivCircuitExecHelloTimer OBJECT-TYPE
SYNTAX INTEGER (1..8191)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This value determines the frequency of Routing Hello
DECnet Phase IV MIB Working Group [Page 27]
RFC 1289 DECnet Phase IV MIB December 1991
messages sent to the adjacent node on the circuit."
::= { phivCircuitParametersEntry 10 }
-- Circuit Counters Table
phivCircuitCountTable OBJECT-TYPE
SYNTAX SEQUENCE OF PhivCircuitCountEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Information about the counters associated with all
circuits currently known."
::= { circuit 2 }
phivCircuitCountEntry OBJECT-TYPE
SYNTAX PhivCircuitCountEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Counter information about all circuits currently known"
INDEX { phivCircuitIndex }
::= { phivCircuitCountTable 1 }
PhivCircuitCountEntry ::=
SEQUENCE {
phivCircuitCountSecLastZeroed
PhivCounter (0..65535),
phivCircuitCountTermPacketsRecd
PhivCounter,
phivCircuitCountOriginPackSent
PhivCounter,
phivCircuitCountTermCongLoss
PhivCounter (0..65535),
phivCircuitCountCorruptLoss
PhivCounter (0..255),
phivCircuitCountTransitPksRecd
PhivCounter,
phivCircuitCountTransitPkSent
PhivCounter,
phivCircuitCountTransitCongestLoss
PhivCounter (0..65535),
phivCircuitCountCircuitDown
PhivCounter (0..255),
phivCircuitCountInitFailure
PhivCounter (0..255),
phivCircuitCountAdjDown
PhivCounter,
DECnet Phase IV MIB Working Group [Page 28]
RFC 1289 DECnet Phase IV MIB December 1991
phivCircuitCountPeakAdj
PhivCounter,
phivCircuitCountBytesRecd
PhivCounter,
phivCircuitCountBytesSent
PhivCounter,
phivCircuitCountDataBlocksRecd
PhivCounter (0..65535),
phivCircuitCountDataBlocksSent
PhivCounter,
phivCircuitCountUsrBuffUnav
PhivCounter (0..65535)
}
phivCircuitCountSecLastZeroed OBJECT-TYPE
SYNTAX PhivCounter (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of seconds since the circuit counters for this
circuit were last zeroed."
::= { phivCircuitCountEntry 1 }
phivCircuitCountTermPacketsRecd OBJECT-TYPE
SYNTAX PhivCounter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of terminating packets received on this circuit."
::= { phivCircuitCountEntry 2 }
phivCircuitCountOriginPackSent OBJECT-TYPE
SYNTAX PhivCounter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of originating packets sent on this circuit."
::= { phivCircuitCountEntry 3 }
phivCircuitCountTermCongLoss OBJECT-TYPE
SYNTAX PhivCounter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of terminating congestion losses on this
circuit."
::= { phivCircuitCountEntry 4 }
DECnet Phase IV MIB Working Group [Page 29]
RFC 1289 DECnet Phase IV MIB December 1991
phivCircuitCountCorruptLoss OBJECT-TYPE
SYNTAX PhivCounter (0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of corruption losses on this circuit."
::= { phivCircuitCountEntry 5 }
phivCircuitCountTransitPksRecd OBJECT-TYPE
SYNTAX PhivCounter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of Transit packets received on this circuit."
::= { phivCircuitCountEntry 6 }
phivCircuitCountTransitPkSent OBJECT-TYPE
SYNTAX PhivCounter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of transit packets sent on this circuit."
::= { phivCircuitCountEntry 7 }
phivCircuitCountTransitCongestLoss OBJECT-TYPE
SYNTAX PhivCounter (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of transit congestion losses on this circuit."
::= { phivCircuitCountEntry 8 }
phivCircuitCountCircuitDown OBJECT-TYPE
SYNTAX PhivCounter (0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of circuit downs on this circuit."
::= { phivCircuitCountEntry 9 }
phivCircuitCountInitFailure OBJECT-TYPE
SYNTAX PhivCounter (0..255)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of Initialization failures on this circuit."
::= { phivCircuitCountEntry 10 }
DECnet Phase IV MIB Working Group [Page 30]
RFC 1289 DECnet Phase IV MIB December 1991
phivCircuitCountAdjDown OBJECT-TYPE
SYNTAX PhivCounter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This counter indicates the number of adjacency losses
that result from any of the following:
Node listener timeout
Invalid data received at node listener
Unexpected control (initialization or verification)
message received
Routing message received with a checksum error
Node identification from a routing message or a
Hello message that is not the one expected Hello
message received indicating that connectivity
became one-way
Adjacency idled."
::= { phivCircuitCountEntry 11 }
phivCircuitCountPeakAdj OBJECT-TYPE
SYNTAX PhivCounter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This counter indicates the maximum number of nodes
that are up on the circuit."
::= { phivCircuitCountEntry 12 }
phivCircuitCountBytesRecd OBJECT-TYPE
SYNTAX PhivCounter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of bytes received on this circuit."
::= { phivCircuitCountEntry 13 }
phivCircuitCountBytesSent OBJECT-TYPE
SYNTAX PhivCounter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of bytes sent on this circuit."
::= { phivCircuitCountEntry 14 }
phivCircuitCountDataBlocksRecd OBJECT-TYPE
SYNTAX PhivCounter
ACCESS read-only
STATUS mandatory
DECnet Phase IV MIB Working Group [Page 31]
RFC 1289 DECnet Phase IV MIB December 1991
DESCRIPTION
"Number of data blocks received on this circuit."
::= { phivCircuitCountEntry 15 }
phivCircuitCountDataBlocksSent OBJECT-TYPE
SYNTAX PhivCounter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of data blocks sent on this circuit."
::= { phivCircuitCountEntry 16 }
phivCircuitCountUsrBuffUnav OBJECT-TYPE
SYNTAX PhivCounter (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of user buffer unavailable errors."
::= { phivCircuitCountEntry 17 }
-- Additional Circuit Parameters
phivCircuitOrigQueueLimit OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This parameter indicates the maximum number of
originating packets that may be outstanding on this
circuit. This does not include route-thru traffic."
::= { circuit 3 }
phivCircuitCountZeroCount OBJECT-TYPE
SYNTAX INTEGER {
other (1),
reset (2)
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"When this value is set to 2, all of the counters in the
Circuit Counter Table are set to zero."
::= { circuit 4 }
-- DDCMP Circuit Group
-- The implementation of the DDCMP Circuit Group is mandatory for
-- all systems which support DDCMP circuits.
DECnet Phase IV MIB Working Group [Page 32]
RFC 1289 DECnet Phase IV MIB December 1991
-- DDCMP Parameters Table
phivDDCMPCircuitParametersTable OBJECT-TYPE
SYNTAX SEQUENCE OF PhivDDCMPCircuitParametersEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Information about DDCMP circuit p