📄 rfc1289.txt
字号:
executor node and the time that process accepts or
rejects it. If the connect is not accepted or rejected
by the user within the number of seconds specified,
Session Control rejects it for the user. A 0
indicates no timer is running."
::= { session 2 }
phivSessionOutTimer OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This value represents the duration between the time the
executor requests a connect and the time that connect is
acknowledged by the destination node. If the connect is
not acknowledged within the number of seconds
specified, Session Control returns an error. A 0
indicates no timer is running."
::= { session 3 }
-- End Communication Layer Group
-- The implementation of the End Communication Layer Group is
-- mandatory for all systems that implement end layer
-- communications.
-- Remote State Table
DECnet Phase IV MIB Working Group [Page 7]
RFC 1289 DECnet Phase IV MIB December 1991
phivEndRemoteTable OBJECT-TYPE
SYNTAX SEQUENCE OF PhivEndRemoteEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Information about the state of sessions between the
node under study and the nodes found in the table."
::= { end 1 }
phivEndRemoteEntry OBJECT-TYPE
SYNTAX PhivEndRemoteEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Information about a particular remote node as seen
from the end communication layer."
INDEX { phivEndRemoteHostNodeID }
::= { phivEndRemoteTable 1 }
PhivEndRemoteEntry ::=
SEQUENCE {
phivEndRemoteHostNodeID
PhivAddr,
phivEndRemoteState
INTEGER,
phivEndCircuitIndex
INTEGER,
phivEndActiveLinks
INTEGER,
phivEndDelay
INTEGER (0..65535)
}
phivEndRemoteHostNodeID OBJECT-TYPE
SYNTAX PhivAddr -- OCTET STRING (SIZE (2))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value is the address of the remote node to be
evaluated."
::= { phivEndRemoteEntry 1 }
phivEndRemoteState OBJECT-TYPE
SYNTAX INTEGER {
on (1),
off (2),
shut (3),
restricted (4)
DECnet Phase IV MIB Working Group [Page 8]
RFC 1289 DECnet Phase IV MIB December 1991
}
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This represents the operational state of the remote node
being evaluated.
The possible states are:
ON Allows logical links.
OFF Allows no new links, terminates existing
links, and stops routing traffic through.
SHUT Allows no new logical links, does not
destroy existing logical links, and goes
to the OFF state when all logical links are
gone.
RESTRICTED Allows no new incoming logical links from
other nodes.
NOTE: These values are incremented by one compared to
the standard DECnet values in order to maintain
compliance with RFC 1155."
::= { phivEndRemoteEntry 2 }
phivEndCircuitIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"A unique index value for each known circuit used to
communicate with the remote node. This is the same
value as phivCircuitIndex."
::= { phivEndRemoteEntry 3 }
phivEndActiveLinks OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This read-only parameter represents the number of active
logical links from the executor to the destination node."
::= { phivEndRemoteEntry 4 }
phivEndDelay OBJECT-TYPE
SYNTAX INTEGER (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This read-only parameter is the average round trip
DECnet Phase IV MIB Working Group [Page 9]
RFC 1289 DECnet Phase IV MIB December 1991
delay in seconds to the destination node. This
parameter is kept on a remote node basis."
::= { phivEndRemoteEntry 5 }
-- End System Counter Table
phivEndCountTable OBJECT-TYPE
SYNTAX SEQUENCE OF PhivEndCountEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Information about the counters associated with each end
system that is known to the entity. These counters
reflect totals from the perspective of the executor
node."
::= { end 2 }
phivEndCountEntry OBJECT-TYPE
SYNTAX PhivEndCountEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Information about a particular session between two end
systems."
INDEX { phivEndCountHostNodeID }
::= { phivEndCountTable 1 }
PhivEndCountEntry ::=
SEQUENCE {
phivEndCountHostNodeID
PhivAddr,
phivEndCountSecsLastZeroed
PhivCounter (0..65535),
phivEndCountUsrBytesRec
PhivCounter,
phivEndCountUsrBytesSent
PhivCounter,
phivEndUCountUsrMessRec
PhivCounter,
phivEndCountUsrMessSent
PhivCounter,
phivEndCountTotalBytesRec
PhivCounter,
phivEndCountTotalBytesSent
PhivCounter,
phivEndCountTotalMessRec
PhivCounter,
phivEndCountTotalMessSent
DECnet Phase IV MIB Working Group [Page 10]
RFC 1289 DECnet Phase IV MIB December 1991
PhivCounter,
phivEndCountConnectsRecd
PhivCounter (0..65535),
phivEndCountConnectsSent
PhivCounter (0..65535),
phivEndCountReponseTimeouts
PhivCounter (0..65535),
phivEndCountRecdConnectResErrs
PhivCounter (0..65535)
}
phivEndCountHostNodeID OBJECT-TYPE
SYNTAX PhivAddr -- OCTET STRING (SIZE (2))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value is the address of the remote node to be
evaluated."
::= { phivEndCountEntry 1 }
phivEndCountSecsLastZeroed OBJECT-TYPE
SYNTAX PhivCounter (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"This value is the number of seconds that have elapsed
since the counters for the node in this table row were
last set to zero. This counter is located in the
network management layer, but is returned with the
end system information which follows."
::= { phivEndCountEntry 2 }
phivEndCountUsrBytesRec OBJECT-TYPE
SYNTAX PhivCounter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of user bytes received from the target host."
::= { phivEndCountEntry 3 }
phivEndCountUsrBytesSent OBJECT-TYPE
SYNTAX PhivCounter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of user bytes sent to the target host."
::= { phivEndCountEntry 4 }
DECnet Phase IV MIB Working Group [Page 11]
RFC 1289 DECnet Phase IV MIB December 1991
phivEndUCountUsrMessRec OBJECT-TYPE
SYNTAX PhivCounter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of user messages received from the target host."
::= { phivEndCountEntry 5 }
phivEndCountUsrMessSent OBJECT-TYPE
SYNTAX PhivCounter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of user messages sent to the target host."
::= { phivEndCountEntry 6 }
phivEndCountTotalBytesRec OBJECT-TYPE
SYNTAX PhivCounter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of bytes received from the target host."
::= { phivEndCountEntry 7 }
phivEndCountTotalBytesSent OBJECT-TYPE
SYNTAX PhivCounter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of bytes sent to the target host."
::= { phivEndCountEntry 8 }
phivEndCountTotalMessRec OBJECT-TYPE
SYNTAX PhivCounter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of messages received from the target host."
::= { phivEndCountEntry 9 }
phivEndCountTotalMessSent OBJECT-TYPE
SYNTAX PhivCounter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of messages sent to the target host."
::= { phivEndCountEntry 10 }
DECnet Phase IV MIB Working Group [Page 12]
RFC 1289 DECnet Phase IV MIB December 1991
phivEndCountConnectsRecd OBJECT-TYPE
SYNTAX PhivCounter (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of connects received from the target host."
::= { phivEndCountEntry 11 }
phivEndCountConnectsSent OBJECT-TYPE
SYNTAX PhivCounter (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of connects sent to the target host."
::= {phivEndCountEntry 12 }
phivEndCountReponseTimeouts OBJECT-TYPE
SYNTAX PhivCounter (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of response timeouts."
::= { phivEndCountEntry 13 }
phivEndCountRecdConnectResErrs OBJECT-TYPE
SYNTAX PhivCounter (0..65535)
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Number of received connect resource errors."
::= {phivEndCountEntry 14 }
-- additional End System objects
phivEndMaxLinks OBJECT-TYPE
SYNTAX INTEGER (1..65535)
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This value represents the maximum active logical
link count allowed for the executor."
::= { end 3 }
phivEndNSPVers OBJECT-TYPE
SYNTAX DisplayString (SIZE (0..255) )