        DESCRIPTION
            "This value indicates whether or not Network Management
            allows service operations on a circuit. The values for
            service-control are as follows:

            ENABLED     SERVICE state and/or service functions are
                        allowed.

            DISABLED    SERVICE state and/or service functions are not
                        allowed.

            NOTE: These values are incremented by one compared to the
            standard DECnet values in order to maintain compliance
            with RFC 1155."
        ::= { phivCircuitParametersEntry 8 }

   phivCircuitExecCost OBJECT-TYPE
        SYNTAX INTEGER (1..25)
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "This value represents the routing cost of the circuit.
            Routing sends messages along the path between two nodes
            having the smallest cost."
        ::= { phivCircuitParametersEntry 9 }

   phivCircuitExecHelloTimer OBJECT-TYPE
        SYNTAX INTEGER (1..8191)
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "This value determines the frequency of Routing Hello
            messages sent to the adjacent node on the circuit."
        ::= { phivCircuitParametersEntry 10 }

   -- Circuit Counters Table

   phivCircuitCountTable OBJECT-TYPE
        SYNTAX SEQUENCE OF PhivCircuitCountEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
            "Information about the counters associated with all
            circuits currently known."
        ::= { circuit 2 }

          phivCircuitCountEntry OBJECT-TYPE
        SYNTAX PhivCircuitCountEntry



DECnet Phase IV MIB Working Group                              [Page 28]

RFC 1559                  DECnet Phase IV MIB              December 1993


        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
            "Counter information about all circuits currently known"
        INDEX     { phivCircuitIndex }
        ::= { phivCircuitCountTable 1 }

   PhivCircuitCountEntry ::=
        SEQUENCE {
            phivCircuitCountSecLastZeroed
                PhivCounter,
            phivCircuitCountTermPacketsRecd
                PhivCounter,
            phivCircuitCountOriginPackSent
                PhivCounter,
            phivCircuitCountTermCongLoss
                PhivCounter,
            phivCircuitCountCorruptLoss
                PhivCounter,
            phivCircuitCountTransitPksRecd
                PhivCounter,
            phivCircuitCountTransitPkSent
                PhivCounter,
            phivCircuitCountTransitCongestLoss
                PhivCounter,
            phivCircuitCountCircuitDown
                PhivCounter,
            phivCircuitCountInitFailure
                PhivCounter,
            phivCircuitCountAdjDown
                PhivCounter,
            phivCircuitCountPeakAdj
                PhivCounter,
            phivCircuitCountBytesRecd
                PhivCounter,
            phivCircuitCountBytesSent
                PhivCounter,
            phivCircuitCountDataBlocksRecd
                PhivCounter,
            phivCircuitCountDataBlocksSent
                PhivCounter,
            phivCircuitCountUsrBuffUnav
                PhivCounter
        }

   phivCircuitCountSecLastZeroed  OBJECT-TYPE
        SYNTAX PhivCounter (0..65535)
        ACCESS read-only



DECnet Phase IV MIB Working Group                              [Page 29]

RFC 1559                  DECnet Phase IV MIB              December 1993


        STATUS mandatory
        DESCRIPTION
            "Number of seconds since the circuit counters for this
            circuit were last zeroed."
        ::= { phivCircuitCountEntry 1 }

   phivCircuitCountTermPacketsRecd OBJECT-TYPE
        SYNTAX PhivCounter (0..2147483647)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "Number of terminating packets received on this circuit."
        ::= { phivCircuitCountEntry 2 }

   phivCircuitCountOriginPackSent OBJECT-TYPE
        SYNTAX PhivCounter (0..2147483647)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "Number of originating packets sent on this circuit."
        ::= { phivCircuitCountEntry 3 }

   phivCircuitCountTermCongLoss OBJECT-TYPE
        SYNTAX PhivCounter (0..65535)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "Number of terminating congestion losses on this
            circuit."
        ::= { phivCircuitCountEntry 4 }

   phivCircuitCountCorruptLoss OBJECT-TYPE
        SYNTAX PhivCounter (0..255)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "Number of corruption losses on this circuit."
        ::= { phivCircuitCountEntry 5 }

   phivCircuitCountTransitPksRecd OBJECT-TYPE
        SYNTAX PhivCounter (0..2147483647)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "Number of Transit packets received on this circuit."
        ::= { phivCircuitCountEntry 6 }

   phivCircuitCountTransitPkSent OBJECT-TYPE



DECnet Phase IV MIB Working Group                              [Page 30]

RFC 1559                  DECnet Phase IV MIB              December 1993


        SYNTAX PhivCounter (0..2147483647)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "Number of transit packets sent on this circuit."
        ::= { phivCircuitCountEntry 7 }

   phivCircuitCountTransitCongestLoss OBJECT-TYPE
        SYNTAX PhivCounter (0..65535)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "Number of transit congestion losses on this circuit."
        ::= { phivCircuitCountEntry 8 }

   phivCircuitCountCircuitDown OBJECT-TYPE
        SYNTAX PhivCounter (0..255)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "Number of circuit downs on this circuit."
        ::= { phivCircuitCountEntry 9 }

   phivCircuitCountInitFailure OBJECT-TYPE
        SYNTAX PhivCounter (0..255)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "Number of Initialization failures on this circuit."
        ::= { phivCircuitCountEntry 10 }

   phivCircuitCountAdjDown OBJECT-TYPE
        SYNTAX PhivCounter (0..2147483647)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "This counter indicates the number of adjacency losses
            that result from any of the following:
                 Node listener timeout
                 Invalid data received at node listener
                 Unexpected control (initialization or verification)
                     message received
                 Routing message received with a checksum error
                 Node identification from a routing message or a
                 Hello message that is not the one expected Hello
                 message received indicating that connectivity
                 became one-way
                 Adjacency idled."



DECnet Phase IV MIB Working Group                              [Page 31]

RFC 1559                  DECnet Phase IV MIB              December 1993


        ::= { phivCircuitCountEntry 11 }

   phivCircuitCountPeakAdj OBJECT-TYPE
        SYNTAX PhivCounter (0..65535)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "This counter indicates the maximum number of nodes
            that are up on the circuit."
        ::= { phivCircuitCountEntry 12 }

   phivCircuitCountBytesRecd OBJECT-TYPE
        SYNTAX PhivCounter (0..2147483647)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "Number of bytes received on this circuit."
        ::= { phivCircuitCountEntry 13 }

   phivCircuitCountBytesSent OBJECT-TYPE
        SYNTAX PhivCounter (0..2147483647)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "Number of bytes sent on this circuit."
        ::= { phivCircuitCountEntry 14 }

   phivCircuitCountDataBlocksRecd OBJECT-TYPE
        SYNTAX PhivCounter (0..2147483647)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "Number of data blocks received on this circuit."
        ::= { phivCircuitCountEntry 15 }

   phivCircuitCountDataBlocksSent OBJECT-TYPE
        SYNTAX PhivCounter (0..2147483647)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "Number of data blocks sent on this circuit."
        ::= { phivCircuitCountEntry 16 }

   phivCircuitCountUsrBuffUnav OBJECT-TYPE
        SYNTAX PhivCounter (0..65535)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION



DECnet Phase IV MIB Working Group                              [Page 32]

RFC 1559                  DECnet Phase IV MIB              December 1993


            "Number of user buffer unavailable errors."
        ::= { phivCircuitCountEntry 17 }

   -- Additional Circuit Parameters

   phivCircuitOrigQueueLimit OBJECT-TYPE
        SYNTAX INTEGER
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "This parameter indicates the maximum number of
            originating packets that may be outstanding on this
            circuit. This does not include route-thru traffic."
        ::= { circuit 3 }

   phivCircuitCountZeroCount OBJECT-TYPE
        SYNTAX INTEGER {
            other (1),
            reset (2)
        }
        ACCESS read-write
        STATUS mandatory
        DESCRIPTION
            "When this value is set to 2, all of the counters in the
            Circuit Counter Table are set to zero."
        ::= { circuit 4 }

   -- DDCMP Circuit Group

   -- The implementation of the DDCMP Circuit Group is optional.
   -- A system can be said to implement this group if and only if
   -- all objects in this group are implemented.

   -- DDCMP Parameters Table

   phivDDCMPCircuitParametersTable OBJECT-TYPE
        SYNTAX SEQUENCE OF PhivDDCMPCircuitParametersEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION
            "Information about DDCMP circuit parameters."
        ::= { ddcmp 1}

   phivDDCMPCircuitParametersEntry OBJECT-TYPE
        SYNTAX PhivDDCMPCircuitParametersEntry
        ACCESS not-accessible
        STATUS mandatory
        DESCRIPTION



DECnet Phase IV MIB Working Group                              [Page 33]

RFC 1559                  DECnet Phase IV MIB              December 1993


            "Parameters information about DDCMP circuits currently
             known."
        INDEX     { phivDDCMPCircuitIndex }
        ::= { phivDDCMPCircuitParametersTable 1 }

   PhivDDCMPCircuitParametersEntry ::=
        SEQUENCE {
            phivDDCMPCircuitIndex
                INTEGER,
            phivDDCMPCircuitAdjNodeAddr
                INTEGER,
            phivDDCMPCircuitTributary
                INTEGER
        }

   phivDDCMPCircuitIndex OBJECT-TYPE
        SYNTAX INTEGER (1..65535)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "A unique index value for each known DDCMP circuit.
            This is the same value as phivCircuitIndex."
        ::= { phivDDCMPCircuitParametersEntry 1 }

   phivDDCMPCircuitAdjNodeAddr OBJECT-TYPE
        SYNTAX PhivAddr -- OCTET STRING (SIZE (2))
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
            "The address of the adjacent node."
        ::= { phivDDCMPCircuitParametersEntry 2 }

   phivDDCMPCircuitTributary OBJECT-TYPE
        SYNTAX INTEGER (0..255)
        ACCESS read-only
        STATUS mandatory
        DESCRIPTION
    