DESCRIPTION
"The maximum number of X.25 circuits that
can be open at one time for this interface.
A value of zero indicates the interface will
not allow any additional circuits (as it may
soon be shutdown). A value of 2147483647
allows an unlimited number of circuits."
::= { mioxPleEntry 1 }
mioxPleRefusedConnections OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of X.25 calls from a remote
systems to this system that were cleared by
this system. The interface instance should
identify the X.25 interface the call came in
on."
::= { mioxPleEntry 2 }
mioxPleEnAddrToX121LkupFlrs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of times a translation from an
Encapsulated Address to an X.121 address
failed to find a corresponding X.121
address. Encapsulated addresses can be
looked up in the mioxPeerTable or translated
via an algorithm as for the DDN. Addresses
that are successfully recognized do not
increment this counter. Addresses that are
not recognized (reflecting an abnormal
packet delivery condition) increment this
counter.
If an address translation fails, it may be
Throop [Page 6]
RFC 1461 Multiprotocol Interconnect on X.25 MIB May 1993
difficult to determine which PLE entry
should count the failure. In such cases the
first likely entry in this table should be
selected. Agents should record the failure
even if they are unsure which PLE should be
associated with the failure."
::= { mioxPleEntry 3 }
mioxPleLastFailedEnAddr OBJECT-TYPE
SYNTAX OCTET STRING (SIZE(2..128))
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The last Encapsulated address that failed
to find a corresponding X.121 address and
caused mioxPleEnAddrToX121LkupFlrs to be
incremented. The first octet of this object
contains the encapsulation type, the
remaining octets contain the address of that
type that failed. Thus for an IP address,
the length will be five octets, the first
octet will contain 204 (hex CC), and the
last four octets will contain the IP
address. For a snap encapsulation, the
first byte would be 128 (hex 80) and the
rest of the octet string would have the snap
header."
::= { mioxPleEntry 4 }
mioxPleEnAddrToX121LkupFlrTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The most recent value of sysUpTime when the
translation from an Encapsulated Address to
X.121 address failed to find a corresponding
X.121 address."
::= { mioxPleEntry 5 }
mioxPleX121ToEnAddrLkupFlrs OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of times the translation from an
X.121 address to an Encapsulated Address
Throop [Page 7]
RFC 1461 Multiprotocol Interconnect on X.25 MIB May 1993
failed to find a corresponding Encapsulated
Address. Addresses successfully recognized
by an algorithm do not increment this
counter. This counter reflects the number
of times call acceptance encountered the
abnormal condition of not recognizing the
peer."
::= { mioxPleEntry 6 }
mioxPleLastFailedX121Address OBJECT-TYPE
SYNTAX X121Address
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The last X.121 address that caused
mioxPleX121ToEnAddrLkupFlrs to increase."
::= { mioxPleEntry 7 }
mioxPleX121ToEnAddrLkupFlrTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The most recent value of sysUpTime when the
translation from an X.121 address to an
Encapsulated Address failed to find a
corresponding Encapsulated Address."
::= { mioxPleEntry 8 }
mioxPleQbitFailures OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of times a connection was closed
because of a Q-bit failure."
::= { mioxPleEntry 9 }
mioxPleQbitFailureRemoteAddress OBJECT-TYPE
SYNTAX X121Address
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The remote address of the most recent
(last) connection that was closed because of
a Q-bit failure."
::= { mioxPleEntry 10 }
Throop [Page 8]
RFC 1461 Multiprotocol Interconnect on X.25 MIB May 1993
mioxPleQbitFailureTime OBJECT-TYPE
SYNTAX TimeTicks
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The most recent value of sysUpTime when a
connection was closed because of a Q-bit
failure. This will also be the last time
that mioxPleQbitFailures was incremented."
::= { mioxPleEntry 11 }
mioxPleMinimumOpenTimer OBJECT-TYPE
SYNTAX PositiveInteger
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The minimum time in milliseconds this
interface will keep a connection open before
allowing it to be closed. A value of zero
indicates no timer."
DEFVAL { 0 }
::= { mioxPleEntry 12 }
mioxPleInactivityTimer OBJECT-TYPE
SYNTAX PositiveInteger
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The amount of time time in milliseconds
this interface will keep an idle connection
open before closing it. A value of
2147483647 indicates no timer."
DEFVAL { 10000 }
::= { mioxPleEntry 13 }
mioxPleHoldDownTimer OBJECT-TYPE
SYNTAX PositiveInteger
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The hold down timer in milliseconds. This
is the minimum amount of time to wait before
trying another call to a host that was
previously unsuccessful. A value of
2147483647 indicates the host will not be
retried."
DEFVAL { 0 }
::= { mioxPleEntry 14 }
Throop [Page 9]
RFC 1461 Multiprotocol Interconnect on X.25 MIB May 1993
mioxPleCollisionRetryTimer OBJECT-TYPE
SYNTAX PositiveInteger
ACCESS read-write
STATUS mandatory
DESCRIPTION
"The Collision Retry Timer in milliseconds.
The time to delay between call attempts when
the maximum number of circuits is exceeded
in a call attempt."
DEFVAL { 0 }
::= { mioxPleEntry 15 }
mioxPleDefaultPeerId OBJECT-TYPE
SYNTAX InstancePointer
ACCESS read-write
STATUS mandatory
DESCRIPTION
"This identifies the instance of the index
in the mioxPeerTable for the default
parameters to use with this interface.
The entry identified by this object may have
a zero length Encapsulation address and a
zero length X.121 address.
These default parameters are used with
connections to hosts that do not have
entries in the mioxPeerTable. Such
connections occur when using ddn-x25 IP-X.25
address mapping or when accepting
connections from other hosts not in the
mioxPeerTable.
The mioxPeerEncTable entry with the same
index as the mioxPeerTable entry specifies
the call encapsulation types this PLE will
accept for peers not in the mioxPeerTable.
If the mioxPeerEncTable doesn't contain any
entries, this PLE will not accept calls from
entries not in the mioxPeerTable."
::= { mioxPleEntry 16 }
-- ###########################################################
-- Peer Table
-- ###########################################################
Throop [Page 10]
RFC 1461 Multiprotocol Interconnect on X.25 MIB May 1993
-- Systems that implement RFC 1356 must also implement
-- all objects in this group.
mioxPeerTable OBJECT-TYPE
SYNTAX SEQUENCE OF MioxPeerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"This table contains information about the
possible peers this machine may exchange
packets with."
::= { mioxPeer 1 }
mioxPeerEntry OBJECT-TYPE
SYNTAX MioxPeerEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Per peer information."
INDEX { mioxPeerIndex }
::= { mioxPeerTable 1 }
MioxPeerEntry ::= SEQUENCE {