📄 rfc1318.txt
字号:
paraInSigTable OBJECT-TYPE
SYNTAX SEQUENCE OF ParaInSigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"A list of port input control signal entries."
::= { para 3 }
paraInSigEntry OBJECT-TYPE
SYNTAX ParaInSigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Input control signal status for a hardware port."
INDEX { paraInSigPortIndex, paraInSigName }
::= { paraInSigTable 1 }
ParaInSigEntry ::=
SEQUENCE {
paraInSigPortIndex
INTEGER,
paraInSigName
INTEGER,
paraInSigState
Character MIB Working Group [Page 6]
RFC 1318 PARALLEL-PRINTER-LIKE-MIB April 1992
INTEGER,
paraInSigChanges
Counter
}
paraInSigPortIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of paraPortIndex for the port to which
this entry belongs."
::= { paraInSigEntry 1 }
paraInSigName OBJECT-TYPE
SYNTAX INTEGER { power(1), online(2), busy(3),
paperout(4), fault(5) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Identification of a hardware signal."
::= { paraInSigEntry 2 }
paraInSigState OBJECT-TYPE
SYNTAX INTEGER { none(1), on(2), off(3) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The current signal state."
::= { paraInSigEntry 3 }
paraInSigChanges OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of times the signal has changed from
'on' to 'off' or from 'off' to 'on'."
::= { paraInSigEntry 4 }
-- the Output Signal table
paraOutSigTable OBJECT-TYPE
SYNTAX SEQUENCE OF ParaOutSigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
Character MIB Working Group [Page 7]
RFC 1318 PARALLEL-PRINTER-LIKE-MIB April 1992
"A list of port output control signal entries."
::= { para 4 }
paraOutSigEntry OBJECT-TYPE
SYNTAX ParaOutSigEntry
ACCESS not-accessible
STATUS mandatory
DESCRIPTION
"Output control signal status for a hardware port."
INDEX { paraOutSigPortIndex, paraOutSigName }
::= { paraOutSigTable 1 }
ParaOutSigEntry ::=
SEQUENCE {
paraOutSigPortIndex
INTEGER,
paraOutSigName
INTEGER,
paraOutSigState
INTEGER,
paraOutSigChanges
Counter
}
paraOutSigPortIndex OBJECT-TYPE
SYNTAX INTEGER
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The value of paraPortIndex for the port to which
this entry belongs."
::= { paraOutSigEntry 1 }
paraOutSigName OBJECT-TYPE
SYNTAX INTEGER { power(1), online(2), busy(3),
paperout(4), fault(5) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"Identification of a hardware signal."
::= { paraOutSigEntry 2 }
paraOutSigState OBJECT-TYPE
SYNTAX INTEGER { none(1), on(2), off(3) }
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The current signal state."
Character MIB Working Group [Page 8]
RFC 1318 PARALLEL-PRINTER-LIKE-MIB April 1992
::= { paraOutSigEntry 3 }
paraOutSigChanges OBJECT-TYPE
SYNTAX Counter
ACCESS read-only
STATUS mandatory
DESCRIPTION
"The number of times the signal has changed from
'on' to 'off' or from 'off' to 'on'."
::= { paraOutSigEntry 4 }
END
6. Acknowledgements
Based on several private MIBs, this document was produced by the
Character MIB Working Group:
Anne Ambler, Spider
Charles Bazaar, Emulex
Christopher Bucci, Datability
Anthony Chung, Hughes LAN Systems
George Conant, Xyplex
John Cook, Chipcom
James Davin, MIT-LCS
Shawn Gallagher, DEC
Tom Grant, Xylogics
Frank Huang, Emulex
David Jordan, Emulex
Satish Joshi, SynOptics
Frank Kastenholz, Clearpoint
Ken Key, University of Tennessee
Jim Kinder, Fibercom
Rajeev Kochhar, 3Com
John LoVerso, Xylogics
Keith McCloghrie, Hughes LAN Systems
Donald Merritt, BRL
David Perkins, 3Com
Jim Reinstedler, Ungerman-Bass
Marshall Rose, PSI
Ron Strich, SSDS
Dean Throop, DG
Bill Townsend, Xylogics
Jesse Walker, DEC
David Waitzman, BBN
Bill Westfield, cisco
Character MIB Working Group [Page 9]
RFC 1318 PARALLEL-PRINTER-LIKE-MIB April 1992
7. References
[1] Cerf, V., "IAB Recommendations for the Development of Internet
Network Management Standards", RFC 1052, NRI, April 1988.
[2] Cerf, V., "Report of the Second Ad Hoc Network Management Review
Group", RFC 1109, NRI, August 1989.
[3] Rose M., and K. McCloghrie, "Structure and Identification of
Management Information for TCP/IP-based internets", RFC 1155,
Performance Systems International, Hughes LAN Systems, May 1990.
[4] McCloghrie K., and M. Rose, "Management Information Base for
Network Management of TCP/IP-based internets", RFC 1156, Hughes
LAN Systems, Performance Systems International, May 1990.
[5] Case, J., Fedor, M., Schoffstall, M., and J. Davin, Simple
Network Management Protocol", RFC 1157, SNMP Research,
Performance Systems International, Performance Systems
International, MIT Laboratory for Computer Science, May 1990.
[6] McCloghrie K., and M. Rose, Editors, "Management Information Base
for Network Management of TCP/IP-based internets", RFC 1213,
Performance Systems International, March 1991.
[7] Information processing systems - Open Systems Interconnection -
Specification of Abstract Syntax Notation One (ASN.1),
International Organization for Standardization, International
Standard 8824, December 1987.
[8] Information processing systems - Open Systems Interconnection -
Specification of Basic Encoding Rules for Abstract Notation One
(ASN.1), International Organization for Standardization,
International Standard 8825, December 1987.
[9] Rose, M., and K. McCloghrie, Editors, "Concise MIB Definitions",
RFC 1212, Performance Systems International, Hughes LAN Systems,
March 1991.
[10] Rose, M., Editor, "A Convention for Defining Traps for use with
the SNMP", RFC 1215, Performance Systems International, March
1991.
8. Security Considerations
Security issues are not discussed in this memo.
Character MIB Working Group [Page 10]
RFC 1318 PARALLEL-PRINTER-LIKE-MIB April 1992
9. Author's Address
Bob Stewart
Xyplex, Inc.
330 Codman Hill Road
Boxborough, MA 01719
Phone: (508) 264-9900
EMail: rlstewart@eng.xyplex.com
Character MIB Working Group [Page 11]
⌨️ 快捷键说明
复制代码
Ctrl + C
搜索代码
Ctrl + F
全屏模式
F11
切换主题
Ctrl + Shift + D
显示快捷键
?
增大字号
Ctrl + =
减小字号
Ctrl + -