📄 rfc3202.txt
字号:
CounterBasedGauge64 FROM HCNUM-TC
TEXTUAL-CONVENTION, RowStatus,
TimeStamp FROM SNMPv2-TC
MODULE-COMPLIANCE, OBJECT-GROUP FROM SNMPv2-CONF
ifIndex FROM IF-MIB
DLCI FROM FRAME-RELAY-DTE-MIB;
frsldMIB MODULE-IDENTITY
LAST-UPDATED "200201030000Z" -- January 3, 2002
ORGANIZATION "IETF Frame Relay Service MIB Working Group"
CONTACT-INFO
"IETF Frame Relay Service MIB (frnetmib) Working Group
WG Charter: http://www.ietf.org/html.charters/
frnetmib-charter.html
WG-email: frnetmib@sunroof.eng.sun.com
Subscribe: frnetmib-request@sunroof.eng.sun.com
Email Archive: ftp://ftp.ietf.org/ietf-mail-archive/frnetmib
Steinberger & Nicklass Standards Track [Page 24]
RFC 3202 Frame Relay Service Level Defs MIB January 2002
Chair: Andy Malis
Vivace Networks
Email: Andy.Malis@vivacenetworks.com
WG editor: Robert Steinberger
Paradyne Networks and
Fujitsu Network Communications
Email: robert.steinberger@fnc.fujitsu.com
Co-author: Orly Nicklass
RAD Data Communications Ltd.
EMail: Orly_n@rad.co.il"
DESCRIPTION
"The MIB module to describe generic objects for
FRF.13 Frame Relay Service Level Definitions."
REVISION "200201030000Z" -- January 3, 2002
DESCRIPTION
"Initial version, published as RFC 3202"
::= { mib-2 95 }
--
-- Textual Conventions
--
FrsldTxRP ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The reference point a PVC uses for calculation
of transmitter related statistics.
The valid values for this type of object are as follows:
- srcLocalRP(1) for the local source
- ingTxLocalRP(2) for the local ingress queue input
- tpTxLocalRP(3) for the local traffic policing
- eqiTxLocalRP(4) for the local egress queue input
- eqoTxLocalRP(5) for the local egress queue output
- otherTxLocalRP(6) for any other local transmit point
- srcRemoteRP(7) for the remote source
- ingTxLocalRP(8) for the remote ingress queue input
- tpTxLocalRP(9) for the remote traffic policing
- eqiTxRemoteRP(10) for the remote egress queue input
- eqoTxRemoteRP(11) for the remote egress queue output
- otherTxRemoteRP(12) for any other remote xmit point"
REFERENCE
"FRF.13: Section 2.3"
SYNTAX INTEGER {
srcLocalRP(1),
ingTxLocalRP(2),
tpTxLocalRP(3),
Steinberger & Nicklass Standards Track [Page 25]
RFC 3202 Frame Relay Service Level Defs MIB January 2002
eqiTxLocalRP(4),
eqoTxLocalRP(5),
otherTxLocalRP(6),
srcRemoteRP(7),
ingTxRemoteRP(8),
tpTxRemoteRP(9),
eqiTxRemoteRP(10),
eqoTxRemoteRP(11),
otherTxRemoteRP(12)
}
FrsldRxRP ::= TEXTUAL-CONVENTION
STATUS current
DESCRIPTION
"The reference point a PVC uses for calculation
of receiver related statistics.
The valid values for this object are as follows:
- desLocalRP(1) for the local destination
- ingRxLocalRP(2) for the local ingress queue input
- tpRxLocalRP(3) for the local traffic policing
- eqiRxLocalRP(4) for the local egress queue input
- eqoRxLocalRP(5) for the local egress queue output
- otherRxLocalRP(6) for any other local receive point
- desRemoteRP(7) for the remote destination
- ingRxRemoteRP(8) for the remote ingress input
- tpRxRemoteRP(9) for the remote traffic policing
- eqiRxRemoteRP(10) for the remote egress queue input
- eqoRxRemoteRP(11) for the remote egress queue output
- otherRxRemoteRP(12) for any other remote receive point"
REFERENCE
"FRF.13: Section 2.3"
SYNTAX INTEGER {
desLocalRP(1),
ingRxLocalRP(2),
tpRxLocalRP(3),
eqiRxLocalRP(4),
eqoRxLocalRP(5),
otherRxLocalRP(6),
desRemoteRP(7),
ingRxRemoteRP(8),
tpRxRemoteRP(9),
eqiRxRemoteRP(10),
eqoRxRemoteRP(11),
otherRxRemoteRP(12)
}
--
Steinberger & Nicklass Standards Track [Page 26]
RFC 3202 Frame Relay Service Level Defs MIB January 2002
-- Base Objects
---
frsldObjects OBJECT IDENTIFIER ::= { frsldMIB 1 }
frsldCapabilities OBJECT IDENTIFIER ::= { frsldMIB 2 }
frsldConformance OBJECT IDENTIFIER ::= { frsldMIB 3 }
-- The Frame Relay Service Level Definitions PVC Control Table
--
-- This table is used to define and display the parameters of
-- service level definitions on individual PVCs.
frsldPvcCtrlTable OBJECT-TYPE
SYNTAX SEQUENCE OF FrsldPvcCtrlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The Frame Relay Service Level Definitions
PVC control table."
::= { frsldObjects 1 }
frsldPvcCtrlEntry OBJECT-TYPE
SYNTAX FrsldPvcCtrlEntry
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"An entry in the Frame Relay Service Level
Definitions PVC control table."
INDEX { ifIndex, frsldPvcCtrlDlci,
frsldPvcCtrlTransmitRP, frsldPvcCtrlReceiveRP}
::= { frsldPvcCtrlTable 1 }
FrsldPvcCtrlEntry ::=
SEQUENCE {
--
-- Index Control Variables
--
frsldPvcCtrlDlci DLCI,
frsldPvcCtrlTransmitRP FrsldTxRP,
frsldPvcCtrlReceiveRP FrsldRxRP,
frsldPvcCtrlStatus RowStatus,
--
-- Service Level Definitions Setup Variables
--
frsldPvcCtrlPacketFreq Integer32,
--
-- Delay Specific Setup Variables
--
Steinberger & Nicklass Standards Track [Page 27]
RFC 3202 Frame Relay Service Level Defs MIB January 2002
frsldPvcCtrlDelayFrSize Integer32,
frsldPvcCtrlDelayType INTEGER,
frsldPvcCtrlDelayTimeOut Integer32,
--
-- Data Persistence Control Variables
--
frsldPvcCtrlPurge Integer32,
frsldPvcCtrlDeleteOnPurge INTEGER,
frsldPvcCtrlLastPurgeTime TimeStamp
}
frsldPvcCtrlDlci OBJECT-TYPE
SYNTAX DLCI
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The value of this object is equal to the DLCI
value for this PVC."
::= { frsldPvcCtrlEntry 1 }
frsldPvcCtrlTransmitRP OBJECT-TYPE
SYNTAX FrsldTxRP
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The reference point this PVC uses for calculation
of transmitter related statistics. This object
together with frsldPvcCtrlReceiveRP define the
measurement domain."
REFERENCE
"FRF.13: Section 2.3"
::= { frsldPvcCtrlEntry 2 }
frsldPvcCtrlReceiveRP OBJECT-TYPE
SYNTAX FrsldRxRP
MAX-ACCESS not-accessible
STATUS current
DESCRIPTION
"The reference point this PVC uses for calculation
of receiver related statistics. This object
together with frsldPvcCtrlTransmitRP define the
measurement domain."
::= { frsldPvcCtrlEntry 3 }
frsldPvcCtrlStatus OBJECT-TYPE
SYNTAX RowStatus
MAX-ACCESS read-create
STATUS current
Steinberger & Nicklass Standards Track [Page 28]
RFC 3202 Frame Relay Service Level Defs MIB January 2002
DESCRIPTION
"The status of the current row. This object is
used to add, delete, and disable rows in this
table. When the status changes to active(1) for the
first time, a row will also be added to the data
table below. This row SHOULD not be removed until
the status is changed to deleted.
When this object is set to destroy(6), all associated
sample and data table rows will also be deleted.
When this object is changed from active(1) to any
other valid value, the defined purge behavior will
affect the data and sample tables.
The rows added to this table MUST have a valid
ifIndex and an ifType related to frame relay. Further,
the reference points referred to by frsldPvcCtrlTransmitRP
and frsldPvcCtrlReceiveRP MUST be supported (see the
frsldRPCaps object).
If at any point the row is not in the active(1) state
and the DLCI no longer exists, the state SHOULD
report notReady(3).
The data in this table SHOULD persist through power
cycles. The symantics of readiness for the rows still
applies. This means that it is possible for a row to be
reprovisioned as notReady(3) if the underlying DLCI does
not persist."
::= { frsldPvcCtrlEntry 4 }
frsldPvcCtrlPacketFreq OBJECT-TYPE
SYNTAX Integer32 (0..3600)
UNITS "seconds"
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The frequency in seconds between initiation of
specialized packets used to collect delay and / or
delivery information as supported by the device.
A value of zero indicates that no packets will
be sent."
DEFVAL { 60 }
::= { frsldPvcCtrlEntry 5 }
frsldPvcCtrlDelayFrSize OBJECT-TYPE
SYNTAX Integer32 (1..8188)
UNITS "octets"
Steinberger & Nicklass Standards Track [Page 29]
RFC 3202 Frame Relay Service Level Defs MIB January 2002
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The size of the payload in the frame used for
calculation of network delay."
DEFVAL { 128 }
::= { frsldPvcCtrlEntry 6 }
frsldPvcCtrlDelayType OBJECT-TYPE
SYNTAX INTEGER {
oneWay(1),
roundTrip(2)
}
MAX-ACCESS read-create
STATUS current
DESCRIPTION
"The type of delay measurement performed."
REFERENCE
"FRF.13: Section 3"
::= { frsldPvcCtrlEntry 7 }
frsldPvcCtrlDelayTimeOut OBJECT-TYPE
SYNTAX Integer32 (1..3600)
UNITS "secon