📄 rfc3035.txt
字号:
Davie Standards Track [Page 5]RFC 3035 MPLS using LDP and ATM VC Switching January 2001 for further details. In an ATM-LSR, the label is carried in the VPI/VCI field, or, when two ATM-LSRs are connected via an ATM "Virtual Path", in the VCI field. Labeled packets MUST be transmitted using the null encapsulation, as defined in Section 6.1 of RFC 2684 [5]. In addition, if two LDP peers are connected via an LC-ATM interface, a non-MPLS connection, capable of carrying unlabelled IP packets, MUST be available. This non-MPLS connection is used to carry LDP packets between the two peers, and MAY also be used (but is not required to be used) for other unlabeled packets (such as OSPF packets, etc.). The LLC/SNAP encapsulation of RFC 2684 [5] MUST be used on the non-MPLS connection. It SHOULD be possible to configure an LC-ATM interface with additional VPI/VCIs that are used to carry control information or non-labelled packets. In that case, the VCI values MUST NOT be in the 0-32 range. These may use either the null encapsulation, as defined in Section 6.1 of RFC 2684 [5], or the LLC/SNAP encapsulation, as defined in Section 5.1 of RFC 2684 [5].7.1. Direct Connections We say that two LSRs are "directly connected" over an LC-ATM interface if all cells transmitted out that interface by one LSR will reach the other, and there are no ATM switches between the two LSRs. When two LSRs are directly connected via an LC-ATM interface, they jointly control the allocation of VPIs/VCIs on the interface connecting them. They may agree to use the VPI/VCI field to encode a single label. The default VPI/VCI value for the non-MPLS connection is VPI 0, VCI 32. Other values can be configured, as long as both parties are aware of the configured value. A VPI/VCI value whose VCI part is in the range 0-32 inclusive MUST NOT be used as the encoding of a label. With the exception of these reserved values, the VPI/VCI values used in the two directions of the link MAY be treated as independent spaces. The allowable ranges of VCIs are communicated through LDP.Davie Standards Track [Page 6]RFC 3035 MPLS using LDP and ATM VC Switching January 20017.2. Connections via an ATM VP Sometimes it can be useful to treat two LSRs as adjacent (in some LSP) across an LC-ATM interface, even though the connection between them is made through an ATM "cloud" via an ATM Virtual Path. In this case, the VPI field is not available to MPLS, and the label MUST be encoded entirely within the VCI field. In this case, the default VCI value of the non-MPLS connection between the LSRs is 32. Other values can be configured, as long as both parties are aware of the configured value. The VPI is set to whatever is required to make use of the Virtual Path. A VPI/VCI value whose VCI part is in the range 0-32 inclusive MUST NOT be used as the encoding of a label. With the exception of these reserved values, the VPI/VCI values used in the two directions of the link MAY be treated as independent spaces. The allowable ranges of VPI/VCIs are communicated through LDP. If more than one VPI is used for label switching, the allowable range of VCIs may be different for each VPI, and each range is communicated through LDP.7.3. Connections via an ATM SVC Sometimes it may be useful to treat two LSRs as adjacent (in some LSP) across an LC-ATM interface, even though the connection between them is made through an ATM "cloud" via a set of ATM Switched Virtual Circuits. The current document does not specify the procedure for handling this case. Such procedures can be found in [4]. The procedures described in [4] allow a VCID to be assigned to each such VC, and specify how LDP can be used used to bind a VCID to a FEC. The top label of a received packet would then be inferred (via a one-to-one mapping) from the virtual circuit on which the packet arrived. There would not be a default VPI or VCI value for the non-MPLS connection.8. Label Distribution and Maintenance Procedures This document discusses the use of "downstream-on-demand" label distribution (see [1]) by ATM-LSRs. These label distribution procedures MUST be used by ATM-LSRs that do not support VC-merge, and MAY also be used by ATM-LSRs that do support VC-merge. The procedures differ somewhat in the two cases, however. We therefore describe the two scenarios in turn. We begin by describing theDavie Standards Track [Page 7]RFC 3035 MPLS using LDP and ATM VC Switching January 2001 behavior of members of the Edge Set of an ATM-LSR domain; these "Edge LSRs" are not themselves ATM-LSRs, and their behavior is the same whether the domain contains VC-merge capable LSRs or not.8.1. Edge LSR Behavior Consider a member of the Edge Set of an ATM-LSR domain. Assume that, as a result of its routing calculations, it selects an ATM-LSR as the next hop of a certain FEC, and that the next hop is reachable via a LC-ATM interface. The Edge LSR uses LDP to request a label binding for that FEC from the next hop. The hop count field in the request is set to 1 (but see the next paragraph). Once the Edge LSR receives the label binding information, it may use MPLS forwarding procedures to transmit packets in the specified FEC, using the specified label as an outgoing label. (Or using the VPI/VCI that corresponds to the specified VCID as the outgoing label, if the VCID technique of [4] is being used.) Note: if the Edge LSR's previous hop is using downstream-on-demand label distribution to request a label from the Edge LSR for a particular FEC, and if the Edge LSR is not merging the LSP from that previous hop with any other LSP, and if the request from the previous hop has a hop count of h, then the hop count in the request issued by the Edge LSR should not be set to 1, but rather to h+1. The binding received by the edge LSR may contain a hop count, which represents the number of hops a packet will take to cross the ATM-LSR domain when using this label. If there is a hop count associated with the binding, the ATM-LSR SHOULD adjust a data packet's TTL by this amount before transmitting the packet. In any event, it MUST adjust a data packet's TTL by at least one before transmitting it. The procedures for doing so (in the case of IP packets) are specified in section 10. The procedures for encapsulating the packets are specified in section 9. When a member of the Edge Set of the ATM-LSR domain receives a label binding request from an ATM-LSR, it allocates a label, and returns (via LDP) a binding containing the allocated label back to the peer that originated the request. It sets the hop count in the binding to 1. When a routing calculation causes an Edge LSR to change the next hop for a particular FEC, and the former next hop was in the ATM-LSR domain, the Edge LSR SHOULD notify the former next hop (via LDP) that the label binding associated with the FEC is no longer needed.Davie Standards Track [Page 8]RFC 3035 MPLS using LDP and ATM VC Switching January 20018.2. Conventional ATM Switches (non-VC-merge) When an ATM-LSR receives (via LDP) a label binding request for a certain FEC from a peer connected to the ATM-LSR over a LC-ATM interface, the ATM-LSR takes the following actions: - it allocates a label, - it requests (via LDP) a label binding from the next hop for that FEC; - it returns (via LDP) a binding containing the allocated incoming label back to the peer that originated the request. For purposes of this procedure, we define a maximum hop count value MAXHOP. MAXHOP has a default value of 255, but may be configured to a different value. The hop count field in the request that the ATM-LSR sends (to the next hop LSR) MUST be set to one more than the hop count field in the request that it received from the upstream LSR. If the resulting hop count exceeds MAXHOP, the request MUST NOT be sent to the next hop, and the ATM-LSR MUST notify the upstream neighbor that its binding request cannot be satisfied. Otherwise, once the ATM-LSR receives the binding from the next hop, it begins using that label. The ATM-LSR MAY choose to wait for the request to be satisfied from downstream before returning the binding upstream. This is a form of "ordered control" (as defined in [1] and [2]), in particular "ingress-initiated ordered control". In this case, as long as the ATM-LSR receives from downstream a hop count which is greater than 0 and less than MAXHOP, it MUST increment the hop count it receives from downstream and MUST include the result in the binding it returns upstream. However, if the hop count exceeds MAXHOP, a label binding MUST NOT be passed upstream. Rather, the upstream LDP peer MUST be informed that the requested label binding cannot be satisfied. If the hop count received from downstream is 0, the hop count passed upstream should also be 0; this indicates that the actual hop count is unknown. Alternatively, the ATM-LSR MAY return the binding upstream without waiting for a binding from downstream ("independent" control, as defined in [1] and [2]). In this case, it specifies a hop count of 0 in the binding, indicating that the true hop count is unknown. The correct value for hop count will be returned later, as described below.Davie Standards Track [Page 9]RFC 3035 MPLS using LDP and ATM VC Switching January 2001 Note that an ATM-LSR, or a member of the edge set of an ATM-LSR domain, may receive multiple binding requests for the same FEC from the same ATM-LSR. It MUST generate a new binding for each request (assuming adequate resources to do so), and retain any existing binding(s). For each request received, an ATM-LSR MUST also generate a new binding request toward the next hop for the FEC. When a routing calculation causes an ATM-LSR to change the next hop for a FEC, the ATM-LSR MUST notify the former next hop (via LDP) that the label binding associated with the FEC is no longer needed. When a LSR receives a notification that a particular label binding is no longer needed, the LSR MAY deallocate the label associated with the binding, and destroy the binding. In the case where an ATM-LSR receives such notification and destroys the binding, it MUST notify the next hop for the FEC that the label binding is no longer needed. If a LSR does not destroy the binding, it may re-use the binding only if it receives a request for the same FEC with the same hop count as the request that originally caused the binding to be created. When a route changes, the label bindings are re-established from the point where the route diverges from the previous route. LSRs upstream of that point are (with one exception, noted below) oblivious to the change. Whenever a LSR changes its next hop for a particular FEC, if the new next hop is reachable via an LC-ATM interface, then for each label that it has bound to that FEC, and distributed upstream, it MUST request a new label binding from the new next hop. When an ATM-LSR receives a label binding for a particular FEC from a downstream neighbor, it may already have provided a corresponding label binding for this FEC to an upstream neighbor, either because it is using independent control, or because the new binding from downstream is the result of a routing change. In this case, unless the hop count is 0, it MUST extract the hop count from the new binding and increment it by one. If the new hop count is different from that which was previously conveyed to the upstream neighbor (including the case where the upstream neighbor was given the value 'unknown') the ATM-LSR MUST notify the upstream neighbor of the change. Each ATM-LSR in turn MUST increment the hop count and pass it upstream until it reaches the ingress Edge LSR. If at any point the value of the hop count equals MAXHOP, the ATM-LSR SHOULD withdraw the binding from the upstream neighbor. A hop count of 0 MUST be passed upstream unchanged.Davie Standards Track [Page 10]
⌨️ 快捷键说明
复制代码
Ctrl + C
搜索代码
Ctrl + F
全屏模式
F11
切换主题
Ctrl + Shift + D
显示快捷键
?
增大字号
Ctrl + =
减小字号
Ctrl + -