content.html
来自「ccna」· HTML 代码 · 共 277 行 · 第 1/2 页
HTML
277 行
<table width="90%" cellpadding="0" cellspacing="0" border="0"> <tr> <td class="rlohdr">Project Planning</td> </tr> </table> </td> </tr> <tr> <td bgcolor="#000000"><img height="1" width="2" border="0" src="../../../../../images/ccna/common/transdot.gif"></td><td class="riohdr"><img height="1" width="2" border="0" src="../../../../../images/ccna/common/transdot.gif"></td><td valign="top" class="riohdr">9.1.1</td><td width="100%" class="riohdr"> <table width="90%" cellpadding="0" cellspacing="0" border="0"> <tr> <td class="riohdr">Network installation safety procedures</td> </tr> </table> </td> </tr> <tr> <td colspan="4"> <table width="90%" cellspacing="0" cellpadding="0" border="0"> <tr> <td class="smtext"> <p> </p><table cellpadding="0" cellspacing="0" width="100%" border="0" xmlns:java="http://xml.apache.org/xslt/java"> <tr> <td width="100%"><img height="10" width="1" border="0" src="../../../../../images/ccna/common/transdot.gif"></td> </tr> <tr> <td width="100%"> <table bgcolor="#000000" bordercolor="#000000" cellspacing="0" bordercolorlight="#000000" width="100%" border="0"> <tr> <td width="100%"> <table bgcolor="#FFFFFF" cellspacing="0" cellpadding="2" width="100%" border="0"> <tr> <td valign="middle"><img height="22" width="22" border="0" src="../../../../../images/ccna/common/inotes.gif"></td><td valign="middle"><span class="cstitle">Instructor Note</span></td> </tr> <tr> <td valign="top"> </td><td valign="top"><span class="cstext"> <p>What is the project? The purpose of the structured cabling project is to allow students to apply individual skills learned in class to a real-world network installation. There are several ways to go about the project.</p> <p>First, you could work through chapter 9, skill-building for all the students simultaneously so they can do the individual components of a cable installation prior to the actual installation. This is the preferred method. Or you could teach the skills to a subset of the class and have one member of the group teach the others. Or you could teach the skills on an as-needed basis during the project. Only you can decide what will work best in your classroom.</p> <p>There are many ideas for projects. You could wire the back of your classroom, the area where the semester 2 routers and rack are located. If there is another room or wiring project within your school, you could get permission to perform that project. You could adopt a nearby school that needs wiring and do the work on a Saturday or after school. Or you could participate in local "Net Day" activities if they are available. It is not so much the actual project but the fact that the students do a project -- from start to finish -- that is so vitally important.</p> <p>When wiring in the real world safety must be a priority. First, you will need your principal's permission and possibly permission from the school district or local union representative. Second, you may need permission slips for the students themselves, especially if the project is off-site.</p> <p>Here are some electrical safety tips. You should brainstorm with your students the electrical safety rules you will follow during your installation. Never work on a device (like a hub, switch, router, or PC) with the case open and the line voltage (power cord) plugged in. Test electrical sockets with an appropriate voltage tester or multimeter. Be sure to find the location of electrical conduit and power wires before trying to install any networking cable. Properly ground all networking equipment. Take care never to nick or cut a live 120 VAC line. These are just some of the precautions you should take.</p> <p>There are also mechanical precautions. Whenever drilling or cutting, wear safety glasses. Be careful with bits and blades. Measure twice, cut once is an old saying. It means you should carefully measure before using a tool. Make sure you and your teacher have investigated what you are drilling or cutting into before you drill or cut; you do not want your power tools to come in contact with electrical wiring or other utilities in the wall. Follow practices of general cleanliness. For example, minimizing dust since you will be installing sensitive networking devices. If you must use a ladder, follow proper ladder precautions. Brainstorm with your students other mechanical precautions you can take.</p> <p>If proper precautions are taken, the structured cabling installation can be an extremely fun and rewarding project. But up front you must have strict classroom and team management, for there are plenty of potential hazards given the nature of the work.</p> </span></td> </tr> </table> </td> </tr> </table> </td> </tr> </table><p>The process of installing a network requires constant awareness of safety procedures. Building a network can be thought of as the combination of activities performed by an electrician and a construction worker. In both cases, safety is the primary concern.</p><p>Classroom safety procedures and general safety precautions must be taken while working with both electrical and construction network building materials. These issues can be discussed during class sessions.</p><table cellpadding="0" cellspacing="0" border="0"> <tr> <td width="100%"><img height="10" width="1" border="0" src="../../../../../images/ccna/common/transdot.gif"></td> </tr> <tr> <td width="100%"> <table bgcolor="#000000" bordercolor="#000000" cellspacing="0" bordercolorlight="#000000" width="100%" border="0"> <tr> <td width="100%"> <table bgcolor="#FFFFFF" width="100%" cellspacing="0" cellpadding="3" border="0"> <tr> <td><span class="warning"><b>WARNING:</b><p> <b>Electrical</b> <br>The following list describes some of the precautions that should be taken when working with electrical materials:</p><ul type="disc"><li>Never work on a device (for example, hub, switch, router, or PC) with the case open and the line voltage (power cord) plugged in.</li><li>Test electrical sockets with an appropriate voltage tester or multimeter.</li><li>Locate all electrical conduits and power wires before trying to install any networking cable.</li><li>Properly ground all networking equipment.</li><li>Never cut or nick a live 120 V AC line.</li></ul><p> <b>Construction</b> <br>The following list describes some of the precautions that should be taken when working with electrical materials:</p><ul type="disc"><li>Wear safety glasses whenever drilling or cutting, and use care when handling bits and blades.</li><li>Measure carefully before you cut, drill into, or permanently alter construction materials. "Measure twice, cut once".</li><li>Investigate what is to be drilled or cut into before beginning. Do not let power tools come into contact with electrical wiring or other utilities in the wall.</li><li>Follow practices of general cleanliness (for example minimize dust that can affect sensitive networking devices).</li><li>Follow proper ladder placement and safety procedures whenever using a ladder.</li></ul></span></td> </tr> </table> </td> </tr> </table> </td> </tr> </table><p>These are just some of the safety precautions that a person must take when working with network building materials. Discuss with the instructor and classmates other measures that could be taken to ensure safety for everyone.</p><table cellpadding="0" cellspacing="4" width="63%" border="0" xmlns:java="http://xml.apache.org/xslt/java"> <tr> <td valign="middle" width="8%"><img height="23" width="23" src="../../../../../images/ccna/common/icon2.gif"></td><td valign="middle" width="92%"><span class="cstitle">Web Links</span></td> </tr> <tr> <td valign="middle" width="8%"> </td><td valign="middle" width="92%"><span class="smtext"><a target="_blank" href="http://www.siemon.com/glossary/definitions.html">Cabling Glossary</a></span></td> </tr> </table></td> </tr> </table> </td> </tr></table> <p> </p> <table width="100%" cellspacing="0" cellpadding="2" border="0" valign="bottom"> <tr> <td></td> </tr> </table> </body></html>
⌨️ 快捷键说明
复制代码Ctrl + C
搜索代码Ctrl + F
全屏模式F11
增大字号Ctrl + =
减小字号Ctrl + -
显示快捷键?