resourcecontent.html
来自「ccna」· HTML 代码 · 共 442 行 · 第 1/2 页
HTML
442 行
</tr><tr><td class="smtext" colspan="1" rowspan="1" width="33%">WIRE SIZE</td><td class="smtext" colspan="1" rowspan="1" width="33%">AWG 24 </td><td class="smtext" colspan="1" rowspan="1" width="34%">N/A</td></tr><tr><td class="smtext" colspan="1" rowspan="1" width="33%">CAL to CABLE? </td><td class="smtext" colspan="1" rowspan="1" width="33%">NO</td><td class="smtext" colspan="1" rowspan="1" width="34%">NO</td></tr><tr><td class="smtext" colspan="1" rowspan="1" width="33%">BEEPING: </td><td class="smtext" colspan="1" rowspan="1" width="33%">ON or OFF </td><td class="smtext" colspan="1" rowspan="1" width="34%">ON or OFF</td></tr><tr><td class="smtext" colspan="1" rowspan="1" width="33%">LCD CONTRAST</td><td class="smtext" colspan="1" rowspan="1" width="33%">From 1 thru 10 (brightest)</td><td class="smtext" colspan="1" rowspan="1" width="34%">From 1 thru 10 (brightest)</td></tr></table> </blockquote><p align="left"> <span class="resourceSectionTitle"><span class="resourceRed">Step 2 - Setup the Cable to be Tested (UTP or COAX)</span></span> </p> <blockquote> <p class="smtext">For each cable to be tested use the following procedure, place the near end of the cable into the RJ-45 jack labeled UTP/FTP on the tester. Place the RJ-45-RJ-45 female coupler on the far end of the cable and then insert the Cable Identifier into the other side of the coupler. The coupler and the cable identifier are accessories that come with the Fluke 620 LAN CableMeter. For coax cables, insert one end of the BNC connector into the jack labeled COAX on the tester. Coax cables should not be terminated. If tested with a terminating resistor (50W), the display will be the resistance of the cable plus the terminating resistor.</p> </blockquote><p align="left"> <span class="resourceSectionTitle"><span class="resourceRed">Step 3 - Perform Cable Length Test Function</span></span> </p> <blockquote> <p class="smtext">Using the tester Test function and a Cable ID Unit (for UTP), you can determine the functionality of the cable. Perform a Basic cable Test on each of the cables provided and fill in the following table based on the result for each CAT 5 cable tested. For each cable, write down the number and color, whether the cable is straight-through or crossover or coaxial, the tester screen test results and what you think the problem is. For UTP cables, press the down arrow or up arrow to see all pairs.</p> <table border="1" cellpadding="2" cellspacing="0" width="75%" bordercolor="#000000"><tr><td class="smtext" align="left" colspan="1" rowspan="1" valign="top" width="12%"><b>Cable No</b>.</td><td class="smtext" align="left" colspan="1" rowspan="1" valign="top" width="13%"><b>Cable Color</b></td><td class="smtext" align="left" colspan="1" rowspan="1" valign="top" width="19%"><b>How cable is wired </b>(UTP or coax)</td><td class="smtext" align="left" colspan="1" rowspan="1" valign="top" width="36%"><b>Tester Displayed Test Results </b>(Note: refer to the Fluke manual for detailed description of test results)</td><td class="smtext" align="left" colspan="1" rowspan="1" valign="top" width="20%"><b>Problem </b></td></tr><tr><td class="smtext" colspan="1" rowspan="1" width="12%">1</td><td class="smtext" colspan="1" rowspan="1" width="13%">聽</td><td class="smtext" colspan="1" rowspan="1" width="19%">聽</td><td class="smtext" colspan="1" rowspan="1" width="36%">聽</td><td class="smtext" colspan="1" rowspan="1" width="20%">聽</td></tr><tr><td class="smtext" colspan="1" rowspan="1" width="12%">2</td><td class="smtext" colspan="1" rowspan="1" width="13%">聽</td><td class="smtext" colspan="1" rowspan="1" width="19%">聽</td><td class="smtext" colspan="1" rowspan="1" width="36%">聽</td><td class="smtext" colspan="1" rowspan="1" width="20%">聽</td></tr><tr><td class="smtext" colspan="1" rowspan="1" width="12%">3</td><td class="smtext" colspan="1" rowspan="1" width="13%">聽</td><td class="smtext" colspan="1" rowspan="1" width="19%">聽</td><td class="smtext" colspan="1" rowspan="1" width="36%">聽</td><td class="smtext" colspan="1" rowspan="1" width="20%">聽</td></tr><tr><td class="smtext" colspan="1" rowspan="1" width="12%">4</td><td class="smtext" colspan="1" rowspan="1" width="13%">聽</td><td class="smtext" colspan="1" rowspan="1" width="19%">聽</td><td class="smtext" colspan="1" rowspan="1" width="36%">聽</td><td class="smtext" colspan="1" rowspan="1" width="20%">聽</td></tr></table> </blockquote><p align="left"> <span class="resourceTitle">LAB 5.3.7 CABLE TESTER - LENGTH - ANSWERS</span> </p> <p align="left"> <span class="resourceAnswerSectionTitle">Step 1 - Set the Advanced Cable Tester for the Desired cable (UTP or COAX)</span> </p> <blockquote> <p class="resourceAnswer">These instructions pertain to the Fluke 620 LAN CableMeter. Turn the rotary switch selector on the tester to the LENGTH position. Press the SETUP button to enter the setup mode and observe the LCD screen on the tester. The first option should be CABLE: Press the UP or DOWN buttons until the desired cable type of UTP or COAX (thinnet) is selected. Press ENTER to accept that setting and go to the next one. Continue pressing the UP/DOWN arrows and pressing ENTER until the tester is set to the following cabling characteristics depending on the type of cable you will be testing</p> <table border="1" cellpadding="2" cellspacing="0" width="75%" bordercolor="#000000"><tr><td class="resourceAnswer" colspan="1" rowspan="1" width="33%"><b>Tester Option </b></td><td class="resourceAnswer" colspan="1" rowspan="1" width="33%"><b>Desired Setting - UTP</b></td><td class="resourceAnswer" colspan="1" rowspan="1" width="34%"><b>Desired Setting - COAX</b></td></tr><tr><td class="resourceAnswer" colspan="1" rowspan="1" width="33%">CABLE:</td><td class="resourceAnswer" colspan="1" rowspan="1" width="33%">UTP </td><td class="resourceAnswer" colspan="1" rowspan="1" width="34%">COAX</td></tr><tr><td class="resourceAnswer" colspan="1" rowspan="1" width="33%">WIRING: </td><td class="resourceAnswer" colspan="1" rowspan="1" width="33%">10BASE-T or EIA/TIA 4PR</td><td class="resourceAnswer" colspan="1" rowspan="1" width="34%">10BASE2 or RG58 (thinnet)</td></tr><tr><td class="resourceAnswer" colspan="1" rowspan="1" width="33%">CATEGORY:</td><td class="resourceAnswer" colspan="1" rowspan="1" width="33%">CAT 5</td><td class="resourceAnswer" colspan="1" rowspan="1" width="34%">N/A</td></tr><tr><td class="resourceAnswer" colspan="1" rowspan="1" width="33%">WIRE SIZE</td><td class="resourceAnswer" colspan="1" rowspan="1" width="33%">AWG 24 </td><td class="resourceAnswer" colspan="1" rowspan="1" width="34%">N/A</td></tr><tr><td class="resourceAnswer" colspan="1" rowspan="1" width="33%">CAL to CABLE? </td><td class="resourceAnswer" colspan="1" rowspan="1" width="33%">NO</td><td class="resourceAnswer" colspan="1" rowspan="1" width="34%">NO</td></tr><tr><td class="resourceAnswer" colspan="1" rowspan="1" width="33%">BEEPING: </td><td class="resourceAnswer" colspan="1" rowspan="1" width="33%">ON or OFF </td><td class="resourceAnswer" colspan="1" rowspan="1" width="34%">ON or OFF</td></tr><tr><td class="resourceAnswer" colspan="1" rowspan="1" width="33%">LCD CONTRAST</td><td class="resourceAnswer" colspan="1" rowspan="1" width="33%">From 1 thru 10(brightest)</td><td class="resourceAnswer" colspan="1" rowspan="1" width="34%">From 1 thru 10(brightest)</td></tr></table> </blockquote> <p align="left"> <span class="resourceAnswerSectionTitle">Step 2 - Setup the Cable to be Tested (UTP or COAX)</span> </p> <blockquote> <p class="resourceAnswer">For each cable to be tested use the following procedure, place the near end of the cable into the RJ-45 jack labeled UTP/FTP on the tester. Place the RJ-45-RJ-45 female coupler on the far end of the cable and then insert the Cable Identifier into the other side of the coupler. The coupler and the cable identifier are accessories that come with the Fluke 620 LAN CableMeter. For coax cables, insert one end of the BNC connector into the jack labeled COAX on the tester. Coax cables should not be terminated. If tested with a terminating resistor (50W), the display will be the resistance of the cable plus the terminating resistor.</p> </blockquote> <p align="left"> <span class="resourceAnswerSectionTitle">Step 3 - Perform Cable Length Test Function</span> </p> <blockquote> <p class="resourceAnswer">Using the tester Test function and a Cable ID Unit (for UTP), you can determine the functionality of the cable. Perform a Basic cable Test on each of the cables provided and fill in the following table based on the result for each CAT 5 cable tested. For each cable, write down the number and color, whether the cable is straight-through or crossover or coaxial, the tester screen test results and what you think the problem is. For UTP cables, press the down arrow or up arrow to see all pairs</p> <table border="1" cellpadding="2" cellspacing="0" width="75%" bordercolor="#000000"><tr><td class="resourceAnswer" align="left" colspan="1" rowspan="1" valign="top" width="12%"><b>Cable No</b>.</td><td class="resourceAnswer" align="left" colspan="1" rowspan="1" valign="top" width="13%"><b>Cable Color</b></td><td class="resourceAnswer" align="left" colspan="1" rowspan="1" valign="top" width="19%"><b>How cable is wired </b>(UTP or coax)</td><td class="resourceAnswer" align="left" colspan="1" rowspan="1" valign="top" width="36%"><b>Tester Displayed Test Results </b>(Note: refer to the Fluke manual for detailed description of test results)</td><td class="resourceAnswer" align="left" colspan="1" rowspan="1" valign="top" width="20%"><b>Problem</b></td></tr><tr><td class="resourceAnswer" colspan="1" rowspan="1" width="12%">1</td><td class="resourceAnswer" colspan="1" rowspan="1" width="13%">Red</td><td class="resourceAnswer" colspan="1" rowspan="1" width="19%">straight-through UTP</td><td class="resourceAnswer" colspan="1" rowspan="1" width="36%"><table border="0" bordercolor="#000000"><tr><td class="resourceAnswer" colspan="1" rowspan="1"><b>1 2</b></td><td class="resourceAnswer" colspan="1" rowspan="1"><b>7'</b></td></tr><tr><td class="resourceAnswer" colspan="1" rowspan="1"><b>3 6</b></td><td class="resourceAnswer" colspan="1" rowspan="1"><b>7'</b></td></tr><tr><td class="resourceAnswer" colspan="1" rowspan="1"><b>4 5</b></td><td class="resourceAnswer" colspan="1" rowspan="1"><b>7'</b></td></tr><tr><td class="resourceAnswer" colspan="1" rowspan="1"><b>7 8</b></td><td class="resourceAnswer" colspan="1" rowspan="1"><b>7'</b></td></tr></table> </td><td class="resourceAnswer" colspan="1" rowspan="1" width="20%">Wire is OK for a straight-through. All 4 pairs are 7' long</td></tr><tr><td class="resourceAnswer" colspan="1" rowspan="1" width="12%">2</td><td class="resourceAnswer" colspan="1" rowspan="1" width="13%">Blue</td><td class="resourceAnswer" colspan="1" rowspan="1" width="19%">straight-through UTP</td><td class="resourceAnswer" colspan="1" rowspan="1" width="36%"><table border="0" bordercolor="#000000"><tr><td class="resourceAnswer" colspan="1" rowspan="1"><b>1 2</b></td><td class="resourceAnswer" colspan="1" rowspan="1"><b>12'</b></td></tr><tr><td class="resourceAnswer" colspan="1" rowspan="1"><b>3 6</b></td><td class="resourceAnswer" colspan="1" rowspan="1"><b>12'</b></td></tr><tr><td class="resourceAnswer" colspan="1" rowspan="1"><b>4 5</b></td><td class="resourceAnswer" colspan="1" rowspan="1"><b>12'</b></td></tr><tr><td class="resourceAnswer" colspan="1" rowspan="1"><b>7 8</b></td><td class="resourceAnswer" colspan="1" rowspan="1"><b>12'</b></td></tr></table> </td><td class="resourceAnswer" colspan="1" rowspan="1" width="20%">Wire is OK for a straight-through. All 4 pairs are 12' long</td></tr><tr><td class="resourceAnswer" colspan="1" rowspan="1" width="12%">3</td><td class="resourceAnswer" colspan="1" rowspan="1" width="13%">Black</td><td class="resourceAnswer" colspan="1" rowspan="1" width="19%">Thinnet Coax</td><td class="resourceAnswer" colspan="1" rowspan="1" width="36%"><table border="0" bordercolor="#000000"><tr><td class="resourceAnswer" colspan="1" rowspan="1"><b>COAX</b></td><td class="resourceAnswer" colspan="1" rowspan="1"><b>8'</b></td></tr></table> </td><td class="resourceAnswer" colspan="1" rowspan="1" width="20%">Wire is OK for coax - 8' long</td></tr></table> </blockquote></td> </tr> </table> </td> </tr> </table> </body></html>
⌨️ 快捷键说明
复制代码Ctrl + C
搜索代码Ctrl + F
全屏模式F11
增大字号Ctrl + =
减小字号Ctrl + -
显示快捷键?