          <td width="90%"><font face="Arial" size="3"><font color="#008080"><b><img border="0" src="../../images/arrow_down.gif" width="19" height="12"></b></font><b><font color="#008080">Physical
            length vs. electrical length</font></b></font> <font color="#CCCC00" size="3" face="Arial"><b>::</b></font></td>
          <td width="10%">
            <p align="right"><font face="Arial" size="3" color="#008080"><b>29/55</b></font></td>
        </tr>
      </table>
    </td>
  </tr>
  <tr>
    <td colspan="2">
      <img border="0" src="../../images/transdot.gif" width="1" height="15"></td>
  </tr>
  <tr>
    <td><img border="0" src="../../images/transdot.gif" width="45" height="1"></td>
    <td><font size="2" face="Arial">The physical length of the permanent
      link/channel is the sum of the physical lengths of the cables between the
      two end points.</font>
        <p><font size="2" face="Arial"><b>Requirements</b></font></p>
        <ul>
          <li><font size="2" face="Arial">When physical length is determined
            from electrical length, the physical length of the link calculated
            using the pair with the shortest electrical delay shall be reported
            and used for making the pass or fail decision.&nbsp;</font></li>
          <li><font size="2" face="Arial">The maximum physical length of the
            permanent link shall be 90 m (290 ft) (test equipment cords are
            excluded from the permanent link model). The maximum physical length
            of the channel shall be 100 m (328 ft) (including equipment cords
            and patch cords).&nbsp;</font></li>
          <li><font size="2" face="Arial">The Pass or Fail criteria is based on
            the maximum length allowed for the channel or permanent link given
            in figures 11-1 and 11-2 plus the nominal velocity of propagation (NVP)
            uncertainty of 10 percent.</font></li>
        </ul>
        <blockquote>
          <p><font face="Arial" size="1">NOTE - Calibration of NVP is
          critical to the accuracy of length measurements.</font></p>
        </blockquote>
        <p><font size="2" face="Arial"><b>Recommendations</b></font></p>
        <ul>
          <li><font size="2" face="Arial">The physical length of the permanent
            link/channel may be determined by physically measuring the length(s)
            of the cable(s), determined from the length markings on the cable(s),
            when present, or estimated from the electrical length
            measurement.&nbsp;</font></li>
          <li><font size="2" face="Arial">The electrical length is derived from
            the propagation delay of signals and depends on the construction and
            material properties of the cable.</font></li>
        </ul>
      <p>&nbsp;</p>
    </td>
  </tr>
  <tr>
    <td colspan="2">
      <table border="0" width="100%" cellspacing="0" cellpadding="0">
        <tr>
          <td width="90%"><img border="0" src="../../images/arrow_up.gif" width="19" height="12"><font face="Arial" size="3"><b><font color="#008080">Physical
            length vs. electrical length</font></b></font> <font face="Arial" size="3"><b><font color="#CCCC00">::</font></b></font></td>
          <td width="10%">
            <p align="right"><font face="Arial" size="3" color="#008080"><b>29/55</b></font></td>
        </tr>
      </table>
    </td>
  </tr>
</table>

</body>

</html>

⌨️ 快捷键说明

复制代码Ctrl + C
搜索代码Ctrl + F
全屏模式F11
增大字号Ctrl + =
减小字号Ctrl + -
显示快捷键?