<td width="90%"><font face="Arial" size="3"><font color="#008080"><b><img border="0" src="../../images/arrow_down.gif" width="19" height="12"></b></font></font><b><font size="3" face="Arial" color="#008080">ScTP
cabling grounding and bonding considerations</font></b> <font color="#CCCC00"><b><font face="Arial" size="3">::</font></b></font></td>
<td width="10%">
<p align="right"><font face="Arial" size="3" color="#008080"><b>5/55</b></font></td>
</tr>
</table>
</td>
</tr>
<tr>
<td colspan="2">
<img border="0" src="../../images/transdot.gif" width="1" height="15"></td>
</tr>
<tr>
<td><img border="0" src="../../images/transdot.gif" width="45" height="1"></td>
<td><font face="Arial" size="2"><img border="0" src="1_5a.gif" align="right" width="200" height="139">Grounding
and bonding systems are an integral part of the screened twisted-pair (ScTP)
telecommunications cabling system. In addition to helping protect
personnel and equipment from hazardous voltages, a proper grounding and
bonding system may reduce EMI to and from the telecommunications cabling
system. Improper grounding and bonding can produce induced voltages and
those voltages can disrupt other telecommunications circuits. </font>
<p><font face="Arial" size="2"><b>Requirements</b></font></p>
<p><font face="Arial" size="2">Grounding and bonding shall support
applicable authorities or codes. </font></p>
<ul>
<li><font face="Arial" size="2">In addition, telecommunications
grounding/bonding shall conform to ANSI/TIA/EIA-607
requirements. </font></li>
<li><font face="Arial" size="2">The shield of ScTP cables shall be
bonded to the telecommunication grounding busbar (TGB) in the
telecommunications room. </font></li>
<li><font face="Arial" size="2">At the work area end of the horizontal
cabling, the voltage measured between the shield and the ground wire
of the electrical outlet used to supply power to the workstation shall
not exceed 1.0 V RMS. The cause of any higher voltage should be
removed before using the cabling.</font></li>
</ul>
<blockquote>
<p><font face="Arial" size="1">NOTE: Grounding at the work area is
usually accomplished through the equipment power connection. Shield
connections at the work area are accomplished through an ScTP patch
cord.</font></p>
</blockquote>
<p> </td>
</tr>
<tr>
<td colspan="2">
<table border="0" width="100%" cellspacing="0" cellpadding="0">
<tr>
<td width="90%"><img border="0" src="../../images/arrow_up.gif" width="19" height="12"><b><font size="3" face="Arial" color="#008080">ScTP
cabling grounding and bonding considerations </font></b><font face="Arial" size="3"><b><font color="#CCCC00">::</font></b></font></td>
<td width="10%">
<p align="right"><font face="Arial" size="3" color="#008080"><b>5/55</b></font></td>
</tr>
</table>
</td>
</tr>
</table>
</body>
</html>
⌨️ 快捷键说明
复制代码
Ctrl + C
搜索代码
Ctrl + F
全屏模式
F11
切换主题
Ctrl + Shift + D
显示快捷键
?
增大字号
Ctrl + =
减小字号
Ctrl + -