📄 plot.1g
字号:
.\" SCCSID: @(#)plot.1g 3.1 11/23/87.TH plot 1g .SH Nameplot \- graphics filters.SH Syntax.B plot[\fB\-T\fIterminal\fR\|[\fIraster\fR\|]\|] [\fB\-l\fR#] [\fB\-w\fR#] [\fB\-c\fR#].SH Description.NXR "plot command".NXR "graphics filter".NXA "plot command" "term command".NXAM "plot command" "plot keyword"The .PN plotcommand reads plotting instructions from the standard input and produces plotting instructions fora specified.I terminalon the standard output.For further information see.MS plot 5 ..SH OptionsThe following options are available with the .PN plotcommand..IP \fB\-T\fR\fIterminal\fR 15Uses the specified terminal name as the terminal typefor which plotting instructions are to be generated.If a .I terminaltype is not specified, the environment parameter $TERMis used. For more information, see.MS environ 7 .The .I terminaltype can be one of the following:.RS.IP \fB450\fR 9DASI Hyterm 450 terminal (diablo mechanism)..IP \fB300\fR 9DASI 300 or GSI terminal (diablo mechanism)..IP \fB300S\fR 9DASI 300S terminal (diablo mechanism)..IP "\fB4014 or tek\fP" 9Tektronix 4014 or 4015 with Enhanced Graphics Module.(Use 4013 for Tektronix 4014 or Tektronix 4015 without the Enhanced Graphics Module)..IP \fB4013\fP 9Tektronix 4013 Storage scope.IP \fBaed\fP 9AED 512 color graphics terminal.IP "\fBbitgraph or bg\fP" 9BBN bitgraph graphics terminal.IP \fBcrt\fP 9Any crt capable of running.MS vi 1.IP \fBdumb\fP 9dumb terminals without cursor addressing or line printers.IP \fBgrn\fP 9given a plot file, produces a grn file..IP \fBhp7221\fP 9Hewlett Packard 7221 Graphics terminal..IP \fBhp2648\fP 9Hewlett Packard 2648 Graphics terminal..IP "\fBimagen or ip"\fP 9Imagen laser printer (default 240 DPI resolution)..IP \fBlvp16\fR 9DEC LVP16 Graphics Plotter..IP \fBhp7475a\fR 9HP 7475A Graphics Plotter..IP \fBver\fR 9Versatec D1200A printer-plotter. This version of.PN plotplaces a scan-converted image in .PN /usr/tmp/rasterand sends the result directly to the plotter device rather than tothe standard output. The optional argument causes a previouslyscan-converted file.I rasterto be sent to the plotter..IP \fBvar\fP 9Benson Varian printer-plotter..IP \fBvt125\fP 9DEC vt125 terminal..RE.IP \fIraster\fR 15Is a scan-converted temporary file that is sent directly tothe plotter. The.I rasterfile is only specified with the \-Tver option..RE.PPIf .I terminal is either an lvp16 or a hp7475a, youcan specify the following options. These options mustfollow the \fB\-T\fIterminal\fR option:.IP \fB\-l#\fR 15length of paper window in plotter units (unit scale).IP \fB\-w#\fR width of paper window in plotter units (unit scale).IP \fB\-c#\fR initial pen carousel to be used.SH RestrictionsA lockout protection does not exist for.PN /usr/tmp/raster ..SH Files/usr/bin/t4013.br/usr/bin/aedplot.br/usr/bin/bgplot.br/usr/bin/crtplot.br/usr/bin/dumbplot.br/usr/bin/gigiplot.br/usr/bin/grnplot.br/usr/bin/hpplot.br/usr/bin/hp7221plot.br/usr/bin/implot.br/usr/bin/lvp16.br/usr/bin/tek.br/usr/bin/t450.br/usr/bin/t300.br/usr/bin/t300s.br/usr/bin/vplot.br/usr/tmp/raster.SH See Alsograph(1g), plot(3x), plot(5)
⌨️ 快捷键说明
复制代码
Ctrl + C
搜索代码
Ctrl + F
全屏模式
F11
切换主题
Ctrl + Shift + D
显示快捷键
?
增大字号
Ctrl + =
减小字号
Ctrl + -